Nano-aptamer probes were prepared and used in lateral flow colorimetric assays for the detection of Ochratoxin A (OTA). In this study, two approaches were examined using 5'-biotin-modified OTA aptamers and silver or gold nanoparticles (AgNP or AuNP). The first method used an "adsorption-desorption" approach wherein aptamers were adsorbed onto the metal nanoparticle surface. Upon the addition of OTA, the aptamer binds specifically to the target, releasing the NPs. The above solutions were applied on a lateral flow assay (LFA) and a detection limit of 6.3 nM was achieved with both metal nanoparticles. The second method used a labelled approach based on Linkage Inversion Assembled Nano-Aptasensors (LIANAs) using a DNA linker containing a 5'-5' linkage inversion (5'-5' linker) to assemble biotinylated aptamer-functionalized metal nanoparticles. In the presence of target, OTA specifically binds with its aptamer leading to release of the linker and disassembly of LIANA aggregates into dispersed nanoparticles. The same solutions were applied in LFA format and the lowest detection limit of 0.63 nM was achieved. The results indicated that the LIANA-based LFA strips were more sensitive than the "adsoprtion-desorption" LFAs. Both lateral flow assays are inexpensive, simple, and rapid to perform and produces results visible to the naked-eye.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c8an00963eDOI Listing

Publication Analysis

Top Keywords

lateral flow
16
metal nanoparticles
12
linkage inversion
12
flow assays
8
"adsorption-desorption" approach
8
inversion assembled
8
assembled nano-aptasensors
8
solutions applied
8
detection limit
8
nanoparticles
5

Similar Publications

To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.

View Article and Find Full Text PDF

Background: The UK's National Health Service Test and Trace (NHSTT) program aimed to provide the most effective and accessible SARS-CoV-2 testing approach possible. Early user feedback indicated that there were accessibility issues associated with throat swabbing. We report the results of service evaluations performed by NHSTT to assess the effectiveness and user acceptance of swabbing approaches, as well as qualitative findings of user experiences from research reports, surveys, and incident reports.

View Article and Find Full Text PDF

Lateral flow assay with automatic signal amplification based on delayed substrate release.

Talanta

January 2025

State Key Laboratory of Food Science and Resources, Jiangnan University, Lihu Road 1800, Wuxi, 214122, PR China; School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi, 214122, PR China; International Joint Laboratory on Food Safety, Jiangnan University, Lihu Road 1800, Wuxi, 214122, PR China.

The low sensitivity of Lateral flow assay (LFA) limits its application in rapid detection for trace targets. LFAs with nanozyme (nanozyme-LFA) as signal labels have demonstrated excellent performance in point of care testing (POCT). However, additional operational steps for substrate catalysis in nanozyme LFA are required, which makes the nanozyme-LFA operation complicated.

View Article and Find Full Text PDF

Staphylococcus pseudintermedius is a global animal pathogen. Traditional identification methods are time-consuming necessitating a more efficient approach. This study validated and enhanced the loop-mediated isothermal amplification (LAMP) technique by integration it with a lateral flow dipstick (LFD) assay for the detection of S.

View Article and Find Full Text PDF

A Chromatography Test Strip of Exonuclease III-Amplified Aptamer for Rapid Identification of Prorocentrum minimum.

Mar Biotechnol (NY)

January 2025

School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Wenhua West Road, 2#, Weihai, 264209, People's Republic of China.

Recently, the scale and frequency of harmful algae blooms (HABs) have gradually increased, posing a serious threat to human health, marine ecosystems and economic development. For early warning, a method is required that can quickly detect and monitor microalgae. It is proposed to use aptamer targeted to Prorocentrum minimum, along with exonuclease III (Exo III), gold nanoparticles, target single-stranded DNA and hairpin structure probe to construct a new method, i.