Absolute targeted proteomics typically employs known amounts of synthetic stable isotopically labeled peptides which are mixed with the analyte and analysed by LC-MS to determine the concentration of proteins. In order to obtain more data, we evaluated the use of two different stable isotopes of the same peptide as spike-in for absolute quantification. For this purpose, peptide labeling by reductive amination was applied, which is a mild reaction for dimethylation of amine groups with very high yield. Three different forms can be generated with e.g., light and heavy labels for spike-in peptides, and medium label for endogenous peptides. The method was studied with peptides of apolipoprotein A-I, apolipoprotein B-100, and leucine-rich alpha-2-glycoprotein without and with serum. In serum, the endogenous protein concentrations were measured across four orders of magnitude by the two-point quantification method. Less than 20% of coefficient of variation (CV) values and strong correlation with R of 0.99 across three analytical replicates was observed. Most importantly, the two-point quantification method allows an internal quality control of the spike-in peptide as strong deviations in ratios calculated between the first and second reference indicate a methodical error. Because of the significant lower costs than synthetically stable isotopically labeled peptides, this approach might be particularly interesting for the absolute quantification of multiple proteins.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c8an01081a | DOI Listing |
Skeletal Radiol
December 2024
Department of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Objectives: To assess calf muscle constitution in chronic Achilles tendon disease (ATD) using two-point Dixon-based MRI (2pt-MRI).
Materials And Methods: This retrospective study analyzed 91 patients (36 females; 57.0 ± 14.
Front Vet Sci
September 2024
Department of Veterinary Medical Imaging, College of Veterinary Medicine, Kyungpook National University, Daegu, Republic of Korea.
Introduction: Fatty degeneration of the vertebral bodies and paravertebral muscles is associated with the presence, severity, and prognosis of spinal disease such as intervertebral disc degeneration. Therefore, the fat fraction (FF) of the vertebral bodies and paraspinal muscles has been considered a potential biomarker for assessing the pathophysiology, progression, and treatment response of spinal disease. Magnetic resonance spectroscopy (MRS) is considered the reference standard for fat quantification; however, it has limitations of a long acquisition time and is technically demanding.
View Article and Find Full Text PDFJ Vet Sci
March 2024
Sustainable Swine Research Center, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan.
Eur J Radiol
March 2024
Institute for Diabetes Research and Metabolic Diseases, Helmholtz Munich at the University of Tübingen, Tübingen, Germany; German Center for Diabetes Research (DZD), Tübingen, Germany; Section on Experimental Radiology, Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany. Electronic address:
Purpose: Excess fat accumulation contributes significantly to metabolic dysfunction and diseases. This study aims to systematically compare the accuracy of commercially available Dixon techniques for quantification of fat fraction in liver, skeletal musculature, and vertebral bone marrow (BM) of healthy individuals, investigating biases and sex-specific influences.
Method: 100 healthy White individuals (50 women) underwent abdominal MRI using two-point and multi-echo Dixon sequences.
Adv Physiol Educ
June 2024
Department of Physiology, All India Institute of Medical Sciences, New Delhi, India.
The study aims to develop a novel methodology to demonstrate the vestibulo-ocular reflex (VOR) and nystagmus by caloric stimulation in an undergraduate medical physiology laboratory. The experimental setup involved two sets of electrodes: one set positioned laterally to both eyes, and another set positioned vertically over either the right or left eye. The caloric method is used to stimulate ears, which involves irrigation of warm (44°C) and cold (30°C) water into the ears while maintaining a temperature difference of approximately ±7°C from the body temperature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!