AI Article Synopsis

Article Abstract

Background: When using a dorsal approach for Morton's neuroma excision, the most common complication is recurrent Morton's neuroma. The present cadaveric study demonstrates how far proximally the nerve is resected during a dorsal approach and examines both the laminar spreader and Gelpiretractor to determine which instrument facilitates maximal proximal resection of the nerve.

Methods: This study involved 12 fresh-frozen cadaver specimens, each of which underwent a dorsal approach to the interdigital nerve with proximal resection. Either a laminar spreader or a Gelpi retractor was used to improve visualization of the intermetatarsal space. The interdigital nerve was then resected, and the lengths of the cut nerves were compared based on the retractor employed.

Results: The mean length of proximal resection in the second intermetatarsal space was 2.42 cm when using the laminar spreader and 1.93 cm when using the Gelpi retractor (P = .252). In the third intermetatarsal space, the mean length of proximal resection was 2.14 cm when using the Laminar spreader and 1.48 cm when using the Gelpi retractor (P = .166).

Conclusion: This study demonstrates how far proximal the interdigital nerve is resected during a dorsal approach to Morton's neuroma and shows no statistically significant difference between the Laminar spreader and the Gelpi retractor. Level V: Cadaver study.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1938640018790013DOI Listing

Publication Analysis

Top Keywords

laminar spreader
20
morton's neuroma
16
dorsal approach
16
proximal resection
16
gelpi retractor
16
nerve resected
12
interdigital nerve
12
intermetatarsal space
12
neuroma excision
8
approach morton's
8

Similar Publications

The use of a laminar spreader for the reduction of extra-articular distal radius fractures: A technical trick.

OTA Int

June 2023

Department of Orthopaedic Surgery, Ascension St. Mary's, Saginaw, MI.

Extra-articular distal radius fractures are often accompanied with shortening, loss of radial height, and radial displacement of the articular segment relative to the shaft of the radius, all seen in the coronal plane. Reduction can be somewhat challenging when reliance on traction and ligamentotaxis fails, especially in subacute or osteoporotic fractures. In this technical report, we describe a technique where application of a laminar spreader between the radius and the ulna in the metaphyseal region can easily reduce the fracture and help attain anatomic alignment in the coronal plane.

View Article and Find Full Text PDF

Arthroscopic Laminar Spreader for Rotator Cuff Repair.

Arthrosc Tech

June 2022

Institut de Chirurgie Réparatrice Locomoteur et Sports Nice-Groupe Kantys, Nice, France.

Arthroscopic rotator cuff repair can be challenging and requires adequate visualization and space. However, the narrow subacromial space can make difficult to perform tendon release and repair under arthroscopy. Inadequate visualization may lead to inaccurate suture placement, compromising the reduction and fixation of the repaired rotator cuff tendons.

View Article and Find Full Text PDF

Background: When using a dorsal approach for Morton's neuroma excision, the most common complication is recurrent Morton's neuroma. The present cadaveric study demonstrates how far proximally the nerve is resected during a dorsal approach and examines both the laminar spreader and Gelpiretractor to determine which instrument facilitates maximal proximal resection of the nerve.

Methods: This study involved 12 fresh-frozen cadaver specimens, each of which underwent a dorsal approach to the interdigital nerve with proximal resection.

View Article and Find Full Text PDF

We have devised a medial peri-articular osteotomy, the distal tibial oblique osteotomy (DTOO), and have used this technique since 1994 for ankle osteoarthritis of advanced and late stages associated with varus inclination. This report describes the surgical technique and its applicability. DTOO can be used for cases of varus ankle osteoarthritis with a range of the ankle joint movement of at least 10° or more.

View Article and Find Full Text PDF

Background: Intra-operative sensing technology is an alternative to standard techniques in total knee arthroplasty (TKA) for determining balance by providing quantitative analysis of loads and point of contact throughout a range of motion. We used intra-operative sensing (VERASENSE-OrthoSensor, Inc.) to examine pie-crusting release of the medial collateral ligament in knees with varus deformity (study group) in comparison to a control group where balance was obtained using a classic release technique and assessed using laminar spreaders, spacer blocks, manual stress, and a ruler.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!