We demonstrate a simple all-fiber photonic phase detector that can measure the phase (timing) difference between an optical pulse train and a microwave signal with subfemtosecond resolution and -60  dB-level amplitude-to-phase conversion coefficient. It is based on passive phase biasing of a Sagnac loop by the intrinsic phase shift of a symmetric 3×3 fiber coupler. By eliminating the necessity of magneto-optic components or complex radio frequency (RF) electronics for phase biasing of the Sagnac loop, this phase detector has potential to be implemented as an integrated photonic device as well. When using this device for synchronization between a 250 MHz mode-locked Er-fiber laser and an 8 GHz microwave oscillator, the minimum residual phase noise floor reaches <-154  dBc/Hz (at 8 GHz carrier) with integrated root mean square (rms) timing jitter of 0.97 fs [1 Hz-1 MHz]. The long-term rms timing drift and frequency instability are 0.92 fs (over 5000 s) and 4×10 (at 10,000 s averaging time), respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.43.003997DOI Listing

Publication Analysis

Top Keywords

phase detector
12
phase
8
phase biasing
8
biasing sagnac
8
sagnac loop
8
simple-structured subfemtosecond-resolution
4
subfemtosecond-resolution optical-microwave
4
optical-microwave phase
4
detector demonstrate
4
demonstrate simple
4

Similar Publications

Tocotrienols in Different Parts of Wild L. Populations in Poland.

Molecules

March 2025

Department of Food Technology and Assessment, Institute of Food Sciences, Warsaw University of Life Sciences, Nowoursynowska 166, 02-787 Warsaw, Poland.

St. John's wort ( L.) is a well-known medicinal plant widely used in phytotherapy due to its abundant secondary metabolites with bioactive properties.

View Article and Find Full Text PDF

Accurate determination of volume percentages in three-phase fluids is paramount for the success of various industrial processes, ranging from oil and gas production to chemical engineering. This study presents a comprehensive approach to this challenge by leveraging advanced signal processing techniques and machine learning paradigms. Our methodology integrates the time, frequency, and wavelet transform features extracted from X-ray-based measurement systems whose structure consists of an X-ray tube source, two sodium iodide detectors, and a test pipe, all of which were simulated using the Monte Carlo N Particle code.

View Article and Find Full Text PDF

Diazepam, a widely prescribed benzodiazepine, is frequently used for the management of alcohol withdrawal syndrome, anxiety, seizures, and muscle spasms. Its monitoring is critical due to its potential for abuse and the therapeutic importance of its metabolite nordiazepam. A sustainable and environmentally friendly high-performance liquid chromatography method was developed and validated for the quantification of diazepam and its active metabolite nordiazepam in human plasma samples.

View Article and Find Full Text PDF

A novel and rapid RP-HPLC coupled with nano quantity analyte detector (NQAD) method was developed for determination of ethambutol hydrochloride and (+)2-aminobutanol in drug products. NQAD is an aerosol-based detector that can be used for the direct detection of the substance lacking ultraviolet chromophores. The two highly polar analytes were separated on a C column with mobile phase consists of trifluoroacetic acid solution and methanol and detected with NQAD.

View Article and Find Full Text PDF

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph.

J Vis Exp

February 2025

Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California, Los Angeles; Crump Institute for Molecular Imaging, University of California, Los Angeles; Jonsson Comprehensive Cancer Center, University of California, Los Angeles;

The CrumpCAT is a prototype small-animal X-ray computed tomography (CT) scanner developed at our research institution. The CMOS detector with a maximum frame rate of 29 Hz and similar Tungsten X-ray sources with energies ranging from 50 kVp to 80 kVp are widely used across commercially available preclinical X-ray CT instruments. This makes the described work highly relevant to other institutions, despite the generally perceived wisdom that these detectors are not suitable for gating the high heart rates of mice (~600 beats/min).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!