Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The purpose of this study was to compare management of moderate-severity reactions with and without a visual aid or flowchart in contrast medium reaction simulations.
Subjects And Methods: All attending radiologists and trainees were requested to participate in a contrast medium reaction simulation program, including a moderate-severity reaction scenario, and were randomized to groups having or not having a visual aid. The time to administer intramuscular (IM) epinephrine via automated injector and errors in administration were recorded. After the simulation, all participants completed a survey assessing their comfort in treating reactions to contrast media with and without a visual aid.
Results: A total of 138 participants were divided into 21 sessions in the program, with 68 participants in the moderate-severity reaction scenario. Eleven groups were provided a visual aid; 10 groups were not. Errors in management occurred in 18.2% (2 of 11) of groups with visual aids versus 40% (4 of 10) in groups without (p = 0.35), with epinephrine self-administration reflecting the most common error. Excluding the groups with errors, the mean time to administration of IM epinephrine was 97 seconds with versus 152 seconds without the visual aid (p = 0.04). Of the 138 participants, 97.8% agreed that the poster would aid in medication administration, and 87% agreed that it would help decrease time to administer medications.
Conclusion: A visual aid increased the subjective confidence of radiologists in the dose and route of medication administration in the contrast medium reaction simulation and led to faster administration of epinephrine. Self-administration IM epinephrine errors were common and seen in both groups.