Background: This study reports the validity and effectiveness of a simulation-based compartment syndrome instructional course.

Methods: Six post-graduation year one (PGY1) orthopaedic residents and six PGY5 residents participated in the study. All PGY1 residents participated in a four-hour compartment syndrome training simulation. An anatomic compartment model was used to test needle placement accuracy in four leg muscle compartments. Pre-training, immediate post-training, and one-month post-training performance data were collected from all PGY1 residents, as well as data from a onetime assessment of all PGY5 residents. These assessments included a paper test for lower leg anatomy (anatomy module), a procedural test of needle placement accuracy using an anatomic compartment syndrome simulation module (needle placement module), and an assessment of ability to measure compartment pressure via low cost simulation (pressure measurement module). Face validity of the needle placement module and pressure measurement module were assessed using a structured questionnaire given to all 12 study participants and three orthopaedic faculty.

Results: The PGY1 residents demonstrated significant improvement at immediate post-training in all three assessments compared to their pre-training performances (anatomy p=0.019, needle placement p=0.026, pressure measurement p=0.033 and Objective Structured Assessment of Technical Skill (OSATS) score for pressure measurement p <0.0001). This performance was maintained at the one-month post-training assessment. Immediate post-training and one-month post-training PGY1 resident performances were comparable with PGY5 resident performance in all tests.Fifteen participants rated the face validity of the needle placement and pressure measurement modules. For the needle placement module, 73.3% of participants highly rated (4 out of 5 or greater) for realism, 86.7% highly rated for being an effective tool for teaching, and 80% highly rated for needing the model to be available throughout their training. The pressure measurement module did not receive high face validity ratings.

Conclusions: With minimal, inexpensive training, the performance of junior residents in a compartment syndrome simulation was improved to a level comparable with senior residents. In addition, this performance was maintained at one-month post-training. The compartment syndrome anatomic module had highly-rated face validity.

Clinical Relevance: Training junior residents to accurately diagnose compartment syndrome using a realistic simulation may allow for greater diagnostic accuracy in the clinical setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6047387PMC

Publication Analysis

Top Keywords

needle placement
20
compartment syndrome
16
pressure measurement
16
pgy1 residents
12
simulation-based compartment
8
syndrome instructional
8
pgy5 residents
8
residents participated
8
anatomic compartment
8
test needle
8

Similar Publications

Background: The aim of this study was to compare microwave ablation (MWA) with and without prior placement of an intra-arterial catheter for the purpose of application of contrast medium (CM).

Methods: 148 patients (45 female, 65.1 ± 14.

View Article and Find Full Text PDF

Objective: To discuss the elbow skin fold extension line in Kirschner wire internal fixation of extended supracondylar humeral fractures in children.

Methods: The clinical data of 58 children with extended supracondylar fractures of the humerus who met the selection criteria between August 2021 and July 2024 were retrospectively analyzed. In 28 cases, needle placement of medial epicondyle of humerus was performed with the assistance of the elbow skin fold extension line (study group), and 30 cases were assisted by routine touch of the medial epicondyle of the humerus (control group).

View Article and Find Full Text PDF

In vivo Safety and Feasibility of a Computed Tomography-Guided Robotic Device for Percutaneous Needle Placement in Bone.

J Vasc Interv Radiol

January 2025

Gustave Roussy (GR), Département d'Anesthésie Chirurgie et Interventionnelle (DACI), Service d'Imagerie Thérapeutique, Villejuif France; Centre d'Investigation Clinique BIOTHERIS, INSERM CIC1428, Villejuif, France; Radiologie Interventionnelle, Gustave Roussy, Villejuif, France; Laboratoire de Recherche Translationnelle en Immunothérapie (LRTI), INSERM U1015, Villejuif, France; Faculté de Médecine, Paris-Saclay Université, F-94276 Le Kremlin Bicêtre, France.

Purpose: To evaluate the feasibility and accuracy of a robotic device used clinically in soft tissues (abdomen and lung), modified in design and workflow, to perform needle insertion in percutaneous bone procedures.

Methods: The primary objective was safety (severe complications) of robotic-assisted insertion in this new application. Secondary objectives were feasibility (placement technical success), performance (acceptable insertions rate), accuracy (lateral deviation), number of intermediate CT-scans and tolerance (minor/moderate complications).

View Article and Find Full Text PDF

Laparo-endoscopic hernia surgery is recommended by various international bodies. However, its uptake by general surgeon is low. We aim to assess the impact of Three Dimensional (3D) endovision system in learning laparoscopic transabdominal preperitoneal (TAPP) repair of groin hernia and transferability of skills acquired from 3D to the Two Dimensional (2D) environment.

View Article and Find Full Text PDF

The Role and Future of Artificial Intelligence in Robotic Image-Guided Interventions.

Tech Vasc Interv Radiol

December 2024

Department of Interventional Radiology, MedStar Georgetown University Hospital, Washington, DC. Electronic address:

Artificial intelligence and robotics are transforming interventional radiology, driven by advancements in computer vision, robotics and procedural automation. Historically focused on diagnostics, AI now also enhances procedural capabilities in IR, enabling future robotic systems to handle complex tasks such as catheter manipulation or needle placement with increasing precision and reliability. Early robotic systems in IR demonstrated improved accuracy in both vascular and percutaneous interventions, though none were equipped with automatic decision-making.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!