One-stage exchange of septic shoulder arthroplasty following a standardized treatment algorithm.

J Shoulder Elbow Surg

Department of Joint Replacement, General and Rheumatic Orthopaedics, Orthopaedic Clinic Markgröningen gGmbH, Markgröningen, Germany; Orthopaedic Department, University-Hospital Hamburg-Eppendorf, Hamburg, Germany.

Published: December 2018

Background: Studies on 1-stage exchange in septic shoulder arthroplasty are limited and show a wide variation of treatment strategies. This retrospective study investigated infection-free survival and function of 1-stage exchange of septic shoulder arthroplasty following a standardized treatment algorithm.

Methods: The requirement for 1-stage exchange was an isolated microorganism from synovial fluid aspiration or synovial biopsy with an antibiotic susceptibility profile prior to revision surgery. If no microorganism was isolated or the underlying pathogen was a difficult-to-treat microorganism (not accessible for biofilm-active antibiotics, enterococci, and fungi), 2-stage exchange was performed. Function was assessed by the Constant score.

Results: Fourteen patients were included, with a mean follow-up period of 5.8 years. The most and second most commonly detected microorganisms were Cutibacterium acnes (formerly Propionibacterium acnes), and Staphylococcus epidermidis, respectively. At 1-stage exchange, patients received local and systemic antibiotics based on the susceptibility profile of the microorganism. Twelve patients with insufficient rotator cuffs received reverse shoulder arthroplasty, whereas 2 patients with intact rotator cuffs underwent anatomic total shoulder arthroplasty. The infection-free survival rate at 1 and 5 years was 100% and 93% (95% confidence interval [CI], 59%-99%), respectively, with 1 recurrence of infection 22 months after 1-stage exchange. Another patient with limited range of motion underwent revision 6 months postoperatively, leading to a revision-free survival rate of 93% (95% CI, 59%-99%) and 86% (95% CI, 54%-96%) at 1 and 5 years, respectively. The mean Constant score was 65 (range, 44-95).

Conclusion: One-stage exchange with prior detection of the underlying microorganism provides satisfactory infection-free survival and function.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2018.06.004DOI Listing

Publication Analysis

Top Keywords

shoulder arthroplasty
20
1-stage exchange
20
exchange septic
12
septic shoulder
12
infection-free survival
12
one-stage exchange
8
arthroplasty standardized
8
standardized treatment
8
survival function
8
susceptibility profile
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!