Background In patients with remarkably enlarged cardiac chambers and history of implantation of older types of mitral valve prosthesis, the considerations for reoperative tricuspid valve surgery are not limited to the risks of sternal reentry but also include the dilemma of whether to carry out prophylactic replacement of the normal functioning but outdated prosthesis or leave it in situ. Methods We reviewed our surgical strategy and postoperative 5-year follow-up findings in two patients who underwent redo tricuspid surgery 3 to 4 decades after mechanical mitral valve replacement. Both patients presented with significant symptoms of progressive right heart failure due to severe tricuspid regurgitation, despite optimal medical therapy. Results We found the beating-heart approach to be an effective and safe method for redo tricuspid surgery. Both first-generation mitral mechanical prostheses were not replaced and have remained well functional upon the patients' postoperative 5-year follow-up, respectively. Conclusion For patients with normal functioning first-generation mechanical mitral prostheses, whether to prophylactically replace the prosthesis should be based on an individualized risk-benefit analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0218492318795545 | DOI Listing |
J Cardiothorac Surg
January 2025
Department of Cardiovascular Surgery, The First Affiliated Hospital, School of Medicine, Zhejiang University, 79#, Qingchun Road, Hangzhou, 310003, China.
Background: Dextrocardia is a rare cardiac malposition where the heart's normal orientation is reversed and is most commonly associated with situs inversus totalis (SIT). Such cases are technically challenging when heart surgery is needed, especially re-do surgery.
Case Presentation: A 72-year-old female patient was referred to our hospital with complaints of chest tightness and reduced activity tolerance.
Heart Rhythm
January 2025
Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Electronic address:
Background: Focal pulsed-field ablation (F-PFA) integrated in electroanatomical mapping (EAM) systems allows tailored lesion sets in patients with atrial fibrillation (AF).
Objective: To determine feasibility, safety and 6-months outcome of F-PFA for a tailored substrate-based catheter ablation (CA) approach in patients with AF and advanced atrial substrate.
Methods: Consecutive patients with AF and advanced atrial substrate treated by a F-PFA system (Cardiofocus) through contact-force sensing catheters integrated in EAM systems were prospectively enrolled.
Interdiscip Cardiovasc Thorac Surg
December 2024
Division of Cardiothoracic Surgery, Heart and Lung Institute, The Prince Charles Hospital, Brisbane, QLD, Australia.
Objectives: There is limited consensus on the optimal strategy for surgical treatment of severe tricuspid valve pathology. At our institution, we have implemented a unique technique of using a tricuspid homograft with its supporting apparatus for partial replacement of the native tricuspid valve. We now present the long-term outcomes of these patients.
View Article and Find Full Text PDFCJC Open
December 2024
Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada.
Background: Contemporary surgical approaches for aortic valve replacement (AVR) include full median sternotomy, hemi-sternotomy, and a right anterior mini thoracotomy (RAMT) approach. We report the midterm outcomes of RAMT for isolated AVR.
Methods: A retrospective study was conducted, reporting the midterm outcomes of patients who underwent isolated RAMT AVR.
Einstein (Sao Paulo)
December 2024
Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
A 42-year-old female patient with a surgical history of iliac venous angioplasty with stenting developed dyspnea on exertion 9 months later. Chest computed tomography angiography revealed a fractured vascular stent in the right cardiac chamber. Doppler echocardiography confirmed that the stent was anchored by the tricuspid valve, causing mild obstruction of the right ventricular filling.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!