Secondary EMR data for quality improvement and research: A comparison of manual and electronic data collection from an integrated critical care electronic medical record system.

J Crit Care

Department of Critical Care Medicine, University of Calgary, Foothills Medical Centre, Ground Floor-McCaig Tower, 1403-29 St NW, Calgary, AB T2N 5A1, Canada; O'Brien Institute for Public Health, Cumming School of Medicine, University of Calgary, 3rd Floor TRW Building, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6, Canada; Department of Community Health Sciences, Cumming School of Medicine, University of Calgary, 3D10, 3280 Hospital Dr NW, Calgary, Alberta T2N 4Z6, Canada; Alberta Health Services, Alberta, Canada. Electronic address:

Published: October 2018

Purpose: This study measured the quality of data extracted from a clinical information system widely used for critical care quality improvement and research.

Materials And Methods: We abstracted data from 30 fields in a random sample of 207 patients admitted to nine adult, medical-surgical intensive care units. We assessed concordance between data collected: (1) manually from the bedside system (eCritical MetaVision) by trained auditors, and (2) electronically from the system data warehouse (eCritical TRACER). Agreement was assessed using Cohen's Kappa for categorical variables and intraclass correlation coefficient (ICC) for continuous variables.

Results: Concordance between data sets was excellent. There was perfect agreement for 11/30 variables (35%). The median Kappa score for the 16 categorical variables was 0.99 (IQR 0.92-1.00). APACHE II had an ICC of 0.936 (0.898-0.960). The lowest concordance was observed for SOFA renal and respiratory components (ICC 0.804 and 0.846, respectively). Score translation errors by the manual auditor were the most common source of data discrepancies.

Conclusions: Manual validation processes of electronic data are complex in comparison to validation of traditional clinical documentation. This study represents a straightforward approach to validate the use of data repositories to support reliable and efficient use of high quality secondary use data.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrc.2018.07.021DOI Listing

Publication Analysis

Top Keywords

data
11
quality improvement
8
electronic data
8
critical care
8
concordance data
8
categorical variables
8
secondary emr
4
emr data
4
quality
4
data quality
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!