Smart Card Decontamination in a High-Containment Laboratory.

Health Secur

Lindsay R. Gabbert, MPS, is a Life Scientist at Leidos, and Justin D. Smith, MS, was an ORISE Fellow and a Life Scientist at Leidos; John G. Neilan, PhD, is the Director; and Max V. Rasmussen, PhD, is a Microbiologist; all at the US Department of Homeland Security Science Group, Plum Island Animal Disease Center, Greenport, NY. Geoffrey S. Ferman, MS, is Biological Safety Officer, US Department of Homeland Security, Plum Island Animal Disease Center, Greenport, NY.

Published: December 2018

Validated procedures for decontamination of laboratory surfaces and equipment are essential to biosafety and biorisk programs at high-containment laboratories. Each high-containment laboratory contains a unique combination of surfaces, procedures, and biological agents that require decontamination methods tailored to specific facility practices. The Plum Island Animal Disease Center (PIADC) is a high-containment laboratory operating multiple biosafety level (BSL)-3, ABSL-3, and BSL-3 Ag spaces. The PIADC facility requires the use of federally issued smart cards, called personal identity verification (PIV) cards, to access information technology (IT) networks both outside and within the high-containment laboratory. Because PIV cards may require transit from the BSL-3 to office spaces, a validated procedure for disinfecting PIV card surfaces prior to removal from the laboratory is critical to ensure biosafety and biosecurity. Two high-risk select agents used in the PIADC high-containment laboratory are foot-and-mouth disease virus (FMDV) and swine vesicular disease virus (SVDV). We evaluated disinfection of PIV cards intentionally spotted with FMDV and SVDV using a modified quantitative carrier test and the liquid chemical disinfectant Virkon S. Our experimental design modeled a worst-case scenario of PIV card contamination and disinfection by combining high concentrations of virus dried with an organic soil load and use of aged Virkon S prepared in hard water. Results showed that FMDV and SVDV dried on PIV card surfaces were completely inactivated after immersion for 30 and 60 seconds, respectively, in a 5-day-old solution of 1% Virkon S. Therefore, this study provided internal validation of PIADC biosafety protocols by demonstrating the efficacy of Virkon S to inactivate viruses on contaminated smart cards at short contact times.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6156686PMC
http://dx.doi.org/10.1089/hs.2018.0023DOI Listing

Publication Analysis

Top Keywords

high-containment laboratory
20
piv cards
12
piv card
12
piadc high-containment
8
smart cards
8
card surfaces
8
disease virus
8
fmdv svdv
8
laboratory
7
high-containment
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?