Background And Aims: Endoscopic ultrasound (EUS) elastography is a novel non-invasive technique that can be used for distinguishing benign from malignant pancreatic masses. However, the studies have reported widely varied sensitivities and specificities. A meta-analysis was performed to assess the performance of EUS elastography for the differentiation of benign and malignant pancreatic masses.

Methods: All the eligible studies were searched by PubMed, Medline, Embase, and the Cochrane Library. Sensitivity, specificity, positive likelihood ratio (LR), negative LR, and area under the curve (AUC) were calculated to examine the accuracy.

Results: A total of nineteen studies which included 1687 patients were analyzed. The pooled sensitivity and specificity for the diagnosis of malignant pancreatic masses were 0.98 (95% confidence interval [CI] 0.96-0.99) and 0.63 (95% CI 0.58-0.69) for qualitative EUS elastography, 0.95 (95% CI 0.93-0.97) and 0.61 (95% CI 0.56-0.66) for quantitative EUS elastography, respectively. The positive and negative LR were 2.60 (95% CI 1.84-3.66) and 0.05 (95% CI 0.02-0.10) for qualitative EUS elastography, 2.64 (95% CI 1.82-3.82) and 0.10 (95% CI 0.06-0.16) for quantitative EUS elastography, respectively. The summary diagnostic odds ratio (DOR) and the AUC were 60.59 (95% CI 28.12-130.56) and 0.91 (Q* = 0.842) for qualitative EUS elastography, 30.09 (95% CI 15.40-58.76) and 0.93 (Q* = 0.860) for quantitative EUS elastography.

Conclusions: Our meta-analysis shows that both qualitative and quantitative EUS elastography have high accuracy in the detection of malignant pancreatic masses, which could be used as a valuable complementary method to EUS-FNA for the differentiation of pancreatic masses in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pan.2018.07.008DOI Listing

Publication Analysis

Top Keywords

eus elastography
32
pancreatic masses
20
malignant pancreatic
16
quantitative eus
16
qualitative eus
12
95%
10
elastography
9
eus
9
endoscopic ultrasound
8
benign malignant
8

Similar Publications

Gallbladder carcinoma in the era of artificial intelligence: Early diagnosis for better treatment.

World J Gastrointest Oncol

January 2025

Department of Anatomy, Division of Human Biology, School of Medicine, IMU University, Kuala Lumpur 57000, Kuala Lumpur, Malaysia.

Gallbladder carcinoma (GBC) is the most common malignant tumor of biliary tract, with poor prognosis due to its aggressive nature and limited therapeutic options. Early detection of GBC is a major challenge, with most GBCs being detected accidentally during cholecystectomy procedures for gallbladder stones. This letter comments on the recent article by Deqing in the , which summarized the various current methods used in early diagnosis of GBC, including endoscopic ultrasound (EUS) examination of the gallbladder for high-risk GBC patients, and the use of EUS-guided elastography, contrast-enhanced EUS, trans-papillary biopsy, natural orifice transluminal endoscopic surgery, magnifying endoscopy, choledochoscopy, and confocal laser endomicroscopy when necessary for early diagnosis of GBC.

View Article and Find Full Text PDF

Background And Aims: The differential diagnosis of benign and malignant deep lymph nodes (LNs) has been a significant challenge up until now. Endoscopic ultrasound (EUS) elastography is a real-time imaging technique evaluated in several studies with diverse results. A meta-analysis was performed to assess the performance of EUS elastography for the differentiation of benign and malignant deep LNs.

View Article and Find Full Text PDF
Article Synopsis
  • - Portal hypertension (PH) is a serious complication in liver disease, and endoscopic ultrasound (EUS) is being highlighted as an effective diagnostic tool for its assessment due to its high-resolution imaging capabilities
  • - The review found that EUS not only improves PH evaluation but also includes advanced methods like contrast enhancement and shear-wave elastography to assess liver stiffness, making it less invasive compared to traditional techniques
  • - Despite its advantages, EUS has limitations such as procedural invasiveness and variability in results, necessitating further research and standardization to enhance its clinical application in managing PH
View Article and Find Full Text PDF

Pancreatic Neuroendocrine Neoplasms: Classification and Novel Role of Endoscopic Ultrasound in Diagnosis and Treatment Personalization.

United European Gastroenterol J

November 2024

Pancreato-Biliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Center, IRCCS San Raffaele Scientific Institute, Milan, Italy.

The incidence and prevalence of pancreatic neuroendocrine neoplasms are steadily increasing. These tumors are highly heterogeneous, with treatment options ranging from observation to surgery, and various medical therapies. The choice of treatment is influenced by factors such as tumor stage, grade (proliferative activity), and the presence of hormone-related syndromes.

View Article and Find Full Text PDF

Background And Aims: Non-invasive assessment of liver fibrosis is important in the management of liver disease. EUS-guided shear wave elastography (EUS-SWE) is a newer technology that can measure liver stiffness, thereby estimating hepatic fibrosis. There is limited data comparing EUS-SWE to vibration controlled transient elastography (VCTE) using liver biopsy as the gold standard, and the reproducibility of EUS-SWE measurements is not known.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!