Rationale And Objectives: To evaluate image quality, coronary interpretability and radiation exposure of coronary CT angiography (CCTA) performed in patients with atrial fibrillation (AF) with the latest scanner generation, comparing two different technical approaches. A new scanner that combines a 0.23 mm spatial resolution, a new generation of iterative reconstruction, fast gantry rotation time and the intracycle motion-correction algorithm to improve the temporal resolution was recently introduced in the clinical field.

Materials And Methods: We enrolled 105 consecutive patients with chronic AF who performed CCTA with a whole-heart coverage high-definition CT scanner (16-cm z-axis coverage with 256 detector rows, 0.28 s gantry rotation time). Five of them were excluded for impaired renal function. Patients were randomized between a double acquisition protocol (50 patients, group 1) or a single acquisition protocol (50 patients, group 2). The image quality, coronary segment interpretability and effective dose (ED) of CCTA were assessed.

Results: The mean HR during the scan was 85.6±21 bpm in group 1 vs. 83.7±23 bpm in Group 2, respectively (p < ns). In group 2, overall image quality was high and comparable with that of group 1 (Likert scale =3.2 ± 1.4 vs. 3.3 ± 1.2, p = ns, in group 1 and 2, respectively). Coronary interpretability was high and similar between the two groups (97.5% and 97.1% in group 1 and 2, p = ns, respectively). Mean ED was significantly higher in group 1 than in group 2 (5.3 ± 1.8 mSv vs. 2.7 ± 0.7 mSv, p < 0.001).

Conclusion: The novel whole-heart coverage CT scanner allows to perform CCTA with a single-acquisition protocol with high image quality and low radiation exposure in AF patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2018.07.003DOI Listing

Publication Analysis

Top Keywords

image quality
12
coronary angiography
8
patients atrial
8
atrial fibrillation
8
radiation exposure
8
quality coronary
8
gantry rotation
8
rotation time
8
acquisition protocol
8
protocol patients
8

Similar Publications

Context.—: Generative artificial intelligence (AI) has emerged as a transformative force in various fields, including anatomic pathology, where it offers the potential to significantly enhance diagnostic accuracy, workflow efficiency, and research capabilities.

Objective.

View Article and Find Full Text PDF

Purpose: Identifying muscles linked to postoperative physical function can guide protocols to enhance early recovery following total hip arthroplasty (THA). This study aimed to evaluate the association of preoperative pelvic and thigh muscle volume and quality with early physical function after THA in patients with unilateral hip osteoarthritis (HOA).

Methods: Preoperative Computed tomography (CT) images of 61 patients (eight males and 53 females) with HOA were analyzed.

View Article and Find Full Text PDF

Ultrasound blood flow imaging plays a crucial role in the diagnosis of cardiovascular and cerebrovascular diseases. Conventional ultrafast ultrasound plane-wave imaging techniques have limited capabilities in microvascular imaging. To enhance the quality of blood flow imaging, this study proposes a microbubble-based H-Scan ultrasound imaging technique.

View Article and Find Full Text PDF

Assessing water quality restoration measures in Lake Pampulha (Brazil) through remote sensing imagery.

Environ Sci Pollut Res Int

January 2025

LEESU, Ecole des Ponts Paris Tech, UPEC, AgroParisTech, F-77455 Marne-la-Vallée, Paris, France.

Urban reservoirs are frequently exposed to impacts from high population density, polluting activities, and the absence of environmental control measures and monitoring. In this study, we investigated the use of satellite imagery to assess restoration measures and support decision-making in a hypereutrophic urban reservoir. Since 2016, Lake Pampulha (Brazil) has undergone restoration measures, including the application of Phoslock®, to mitigate its poor water quality conditions.

View Article and Find Full Text PDF

Pathology has benefited from the rapid progress of image-digitizing technology during the last decade. However, the application of digital whole slide images (WSI) in forensic pathology still needs to be improved. WSI validation is crucial to ensure diagnostic performance, at least equivalent to glass slides and light microscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!