A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of Calculated Globulin (CG) as a Screening Test for Antibody Deficiency in an Italian University Hospital. | LitMetric

Validation of Calculated Globulin (CG) as a Screening Test for Antibody Deficiency in an Italian University Hospital.

Curr Pharm Biotechnol

Department of Translational Medical Sciences, Division of Allergy and Clinical Immunology, Center for Basic and Clinical Immunology Research, University of Naples Federico II, Naples, Italy.

Published: February 2019

Background: Morbidity and mortality of primary and secondary antibody deficiencies (AD) are frequently associated with diagnostic delays. These could be avoided by a combination of factors including a widespread and effective development in screening tests.

Methods: Calculated globulin (CG), derived from the difference between serum total protein and albumin levels, reflects immunoglobulin serum levels and has shown to have a predictive value in the early diagnosis of antibody deficiencies. This study investigated the possibility to use low levels of CG to detect antibody deficiency in an Italian University Hospital.

Results: First, we conducted an analysis of anonymized adult samples collected at our biochemistry laboratory with a range of calculated globulin levels from 15 to 22 g/l. A CG cut-off of 19 g/l detected subjects with IgG lower than 600 mg/dl with a sensitivity of 70% and a specificity of 75%. To further verify the clinical usefulness of CG, we retrospectively evaluated the relationship between CG values and serum IgG levels in 38 patients diagnosed with CVID at our Institution. Using a CG cut-off of 19 g/l, we detected antibody deficiency in 97.3% (37/38) of the subjects present in our cohort.

Conclusion: Finally, we chose a CG value of 19 g/l as the cut-off for a prospective AD screening program. The results of this study show that a screening CG test can be used as a tool to reduce diagnostic delays, improve long-term prognosis and reduce the healthcare costs of antibody deficiency.

Download full-text PDF

Source
http://dx.doi.org/10.2174/1389201019666180808163311DOI Listing

Publication Analysis

Top Keywords

antibody deficiency
16
calculated globulin
12
screening test
8
deficiency italian
8
italian university
8
antibody deficiencies
8
diagnostic delays
8
g/l cut-off
8
cut-off g/l
8
g/l detected
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!