Objectives: The aim of this study was to test the hypothesis that magnetic resonance imaging (MRI) of the knee with 10-minute 3-dimensional (3D) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) turbo spin echo (TSE) protocols can replace 20-minute 2-dimensional (2D) TSE standard-of-reference protocols for the diagnosis of internal derangement.
Materials And Methods: After internal review board approval and prospective informed consent, 100 symptomatic subjects underwent MRI of the knee at 3 T and 50 symptomatic subjects at 1.5 T, consisting of 10-minute 3D CAIPIRINHA SPACE TSE and 20-minute standard-of-reference 2D TSE protocols. Two fellowship-trained musculoskeletal radiologists assessed the studies in an anonymized and randomized fashion for structural abnormalities. Descriptive statistics, interreader reliability, intermethod concordance, diagnostic definitiveness, and interchangeability tests were applied. P values equal to or smaller than 0.01 were considered significant.
Results: The interchangeability analysis showed that the 3D MRI can replace the 2D MRI protocols, whereas a superiority of 3D MRI was suggested statistically for the detection of medial and lateral meniscal tears, cartilage defects, and bone marrow edema by significantly higher common pair exact match proportions of readers (P < 0.01, respectively).The overall interreader reliabilities were 89% of exact matches for 2D TSE (κ, 0.842) and 96% of exact matches for 3D TSE (κ, 0.941) (P < 0.01). There was good intermethod concordance (κ, 0.736; range, 0.579-1.000). The interreader reliability (2D TSE: κ, 0.748 [0.603-1.000]; 3D TSE: κ, 0.901 [0.797-1.000]) and diagnostic definitiveness were significantly higher for the 3D than 2D MRI (P < 0.01).
Conclusions: 10-minute 3D CAIPIRINHA SPACE TSE MRI protocols can replace 20-minute 2D TSE standard-of-reference MRI protocols for the evaluation of internal derangement of the knee by producing similar results in individual patient diagnoses, whereas interpretations of 3D CAIPIRINHA SPACE TSE MRI examinations resulted in an overall higher interreader reliability, intermethod concordance, and reader definitiveness.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RLI.0000000000000493 | DOI Listing |
J Magn Reson Imaging
September 2024
Department of Magnetic Resonance, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Background: Middle cerebral artery (MCA) plaques are a leading cause of ischemic stroke (IS). Plaque inflammation is crucial for plaque stability and urgently needs quantitative detection.
Purpose: To explore the utility of Controlled Aliasing in Parallel Imaging Results in Higher Acceleration (CAIPIRINHA)-Dixon-Time-resolved angiography With Interleaved Stochastic Trajectories (TWIST) (CDT) dynamic contrast-enhanced MRI (DCE-MRI) for evaluating MCA culprit plaque inflammation changes over stroke time and with diabetes mellitus (DM).
Magn Reson Med
October 2023
Institute for Medical Imaging Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
Purpose: To propose an acceleration method for 3D variable flip-angle (VFA) T mapping based on a technique called shift undersampling improves parametric mapping efficiency and resolution (SUPER).
Methods: The proposed method incorporates strategies of SUPER, controlled aliasing in volumetric parallel imaging (CAIPIRINHA), and total variation-based regularization to accelerate 3D VFA T mapping. The k-space sampling grid of CAIPIRINHA is internally undersampled with SUPER along the contrast dimension.
Phys Imaging Radiat Oncol
July 2022
Radiology, Centre Oscar Lambret, Lille, 3 Rue Frédéric Combemale, 59000 Lille, France.
Magnetic resonance imaging (MRI) for radiotherapy is often based on 3D acquisitions, but suffers from low signal-to-noise ratio due to immobilization device and flexible coil use. The aim of this study was to investigate if Compressed Sensing (CS) improves image quality for 3D Turbo Spin Echo acquisitions compared with Controlled Aliasing k-space-based parallel imaging in equivalent acquisition time for intracranial T1, T2-Fluid-Attenuated Inversion Recovery (FLAIR) and pelvic T2 imaging. Qualitative ratings suffered from large inter-rater variability.
View Article and Find Full Text PDFEur Radiol
December 2022
Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Hospital/The Johns Hopkins Medical Institutions, 600 North Wolfe Street, Baltimore, MD, 21287, USA.
Objectives: To test whether a 4-fold accelerated 3D T2-weighted (T2) CAIPIRINHA SPACE TSE sequence with isotropic voxel size is equivalent to conventional 2DT2 TSE for the evaluation of intrinsic and perilesional soft tissue tumors (STT) characteristics.
Methods: For 108 patients with histologically-proven STTs, MRI, including 3DT2 (CAIPIRINHA SPACE TSE) and 2DT2 (TSE) sequences, was performed. Two radiologists evaluated each sequence for quality (diagnostic, non-diagnostic), tumor characteristics (heterogeneity, signal intensity, margin), and the presence or absence of cortical involvement, marrow edema, and perilesional edema (PLE); tumor size and PLE extent were measured.
Magn Reson Med
August 2022
Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Purpose: To reduce scan time, methods to accelerate phase-encoded/non-Cartesian MR fingerprinting (MRF) acquisitions for variable density spiral acquisitions have recently been developed. These methods are not applicable to MRF acquisitions, wherein a single k-space spoke is acquired per frame. Therefore, we propose a low-rank inversion method to resolve MRF contrast dynamics from through-plane accelerated Cartesian/radial measurements applied to quantitative relaxation-time mapping on a 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!