Objective: The authors aimed to identify ergonomic smartphone forms by investigating the effects of hand length, four major smartphone dimensions (height, width, thickness, and edge roundness), and smartphone mass on grip comfort and design attractiveness.

Background: Despite their potential effect on grip comfort and design attractiveness, the dimensions specified above have never been simultaneously considered in a study investigating smartphone gripping.

Method: Seventy-two young individuals participated in a three-stage study. Stage 1 determined the ranges of the four smartphone dimensions suitable for grip comfort and identified the strengths of their influences. Stage 2 investigated the effects of width and thickness (determined to have the greatest influence) on grip comfort and design attractiveness. Mock-ups of varying masses were fabricated using the dimensions determined during the first two stages to investigate the effect of mass on grip comfort and design attractiveness in Stage 3.

Results: Phone width was found to significantly influence grip comfort and design attractiveness, and the dimensions of 140 × 65 (or 70) × 8 × 2.5 mm (height × width × thickness × edge roundness) provided high grip comfort and design attractiveness. The selected dimensions were fit with a mass of 122 g, with masses in the range of 106-137 g being comparable.

Conclusion: The findings of this study contribute to ergonomic smartphone design developments by specifying dimensions and mass that provide high grip comfort and design attractiveness.

Application: The dimensions and mass determined in this study should be considered for improving smartphone design grip comfort and attractiveness.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0018720818792758DOI Listing

Publication Analysis

Top Keywords

grip comfort
40
comfort design
28
design attractiveness
20
ergonomic smartphone
12
high grip
12
width thickness
12
grip
10
comfort
10
design
10
smartphone
8

Similar Publications

An origami-based tactile sensory ring utilizing multilayered conductive paper substrates presents an innovative approach to wearable health applications. By harnessing paper's flexibility and employing origami folding, the sensors integrate structural stability and self-packaging without added encapsulation layers. Knot-shaped designs create loop-based systems that secure conductive paper strips and protect sensing layers.

View Article and Find Full Text PDF

Japanese quails () are sensitive to zinc (Zn) deficiency, a mineral essential for growth, development, and bone health. This study evaluated the effects of different levels of Zn in the diet on zootechnical performance, organ and carcass weight, and tibial breakage resistance in quails from 1 to 42 days of age. A 5 × 2 factorial design was used, consisting of five Zn levels (30, 60, 90, 120, and 150 mg/kg) and two thermal environments (thermal comfort and heat stress), with five replicates of 10 birds per treatment.

View Article and Find Full Text PDF

Two approaches to movement selection, if-then rules versus prospective planning, were investigated. Studies have shown that the rule-based approach leads to more efficient movement selection than the plan-based approach, though the resulting movements are the same. This dual-tasking study investigates two hypotheses explaining this discrepancy: The efficiency hypothesis states that the rule-based approach to movement selection is more efficient, and its advantage over the plan-based approach increases under any kind of enhanced task demands.

View Article and Find Full Text PDF

Exploring Factors for Prescription and Validation of Actuated Upper Limb Devices: a Cross-sectional Survey of Allied Health Professionals.

Can Prosthet Orthot J

September 2024

Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, Scotland.

Background: Actuated devices can be beneficial for individuals with upper limb muscle weakness, offering extra force and grip. Utilising this type of assistive device can facilitate daily activities, thereby enhancing independence and overall quality of life. The development of actuated assistive devices has been growing, and current literature shows promise in their clinical use.

View Article and Find Full Text PDF

In forehand strokes with different grips in tennis, the forearm muscle activities, the distribution and attenuation of the impact loads, and the effects of the muscles on the impact load attenuation exhibited different characteristics. This study aimed to explore these characteristics by analyzing electromyography (EMG) and acceleration data, and comparing the differences between the Eastern and Western grips. Fourteen level II or above tennis players (ten males, aged 22.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!