Monolithic alkylsilane column: A promising separation medium for oligonucleotides by ion-pair reversed-phase liquid chromatography.

J Chromatogr A

State Key Laboratory of Analytical Chemistry for Life Science, Collaborative Innovation Center of Chemistry for Life Sciences, School of Chemistry & Chemical Engineering and Center of Materials Analysis, Nanjing University, 163 Xianlin Avenue, Nanjing 210023, China. Electronic address:

Published: September 2018

AI Article Synopsis

  • The study compared the retention behaviors of oligonucleotides using monolithic and particle-packed octadecylsilane columns through ion-pair reversed-phase liquid chromatography (IP-RPLC).
  • Results indicated that hairpin oligonucleotides had weaker retention than random coil oligonucleotides on the monolithic column, while the particle-packed columns showed different retention behaviors.
  • The analysis suggests that the unique pore structure of the monolithic column allows oligonucleotides to maintain their conformations better than in particle-packed columns, highlighting the potential of monolith-based IP-RPLC for studying oligonucleotide behaviors.

Article Abstract

In this paper, a monolithic octadecylsilane column and particle-packed octadecylsilane columns were used to investigate the retention behaviors of oligonucleotides by ion-pair reversed-phase liquid chromatography (IP-RPLC). Results showed that, with same base composition, hairpin oligonucleotides always had weaker retention than corresponding random coil oligonucleotides on the monolithic column, but not on the particle-packed columns. In addition, the linear correlation between the retention factor k of oligonucleotides and the reciprocal of temperature (1/T), especially for hairpins, was relatively weaker on the particle-packed columns, as compared to the correlation on the monolithic column. The correlation between k and 1/T became weaker with decreasing particle size of the particle-packed columns. Moreover, results revealed that the overall retention order on the particle-packed column with small particles (3 μm) differed greatly from that on the monolithic column. In contrast, the retention order on the 10 μm particle-packed column was very close to that on the monolithic column. From the above, we inferred that oligonucleotides could keep their primary conformations unchanged when passing through the monolithic column, attributed to the special pore structures of the monolith. However, the conformations of oligonucleotides were suppressed or even destroyed when oligonucleotides passed through the particle-packed columns. This because the narrow and tortuous channels created by the stacked stationary phase particles could lead to more complex and unequable retention behaviors. Therefore, the monolithic column exhibited better retention regularity for oligonucleotides of secondary structure especially for hairpins than the particle-packed columns. It is noteworthy that the monolith-based IP-RPLC opens an intriguing prospect in accurately elucidating the retention behaviors of oligonucleotides.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2018.07.062DOI Listing

Publication Analysis

Top Keywords

monolithic column
24
particle-packed columns
20
retention behaviors
12
column
10
oligonucleotides
10
monolithic
8
oligonucleotides ion-pair
8
ion-pair reversed-phase
8
reversed-phase liquid
8
liquid chromatography
8