Background And Aims: Endoscopic resection (ER) is safe and effective for Barrett's esophagus (BE) containing high-grade dysplasia (HGD) or mucosal adenocarcinoma (T1A). The risk of metachronous neoplasia is reduced by ablation of residual BE by using radiofrequency ablation (RFA) or argon plasma coagulation (APC). These have not been compared directly. We aimed to recruit up to 100 patients with BE and HGD or T1A confirmed by ER over 1 year in 6 centers in a randomized pilot study.
Methods: Randomization was 1:1 to RFA or APC (4 treatments allowed at 2-month intervals). Recruitment, retention, dysplasia clearance, clearance of benign BE, adverse events, healthcare costs, and quality of life by using EQ-5D, EORTC QLQ-C30, or OES18 were assessed up to the end of the trial at 12 months.
Results: Of 171 patients screened, 76 were randomized to RFA (n = 36) or APC (n = 40). The mean age was 69.7 years, and 82% were male. BE was <5 cm (n = 27), 5 to 10 cm (n = 45), and >10 cm (n = 4). Sixty-five patients completed the trial. At 12 months, dysplasia clearance was RFA 79.4% and APC 83.8% (odds ratio [OR] 0.7; 95% confidence interval [CI], 0.2-2.6); BE clearance was RFA 55.8%, and APC 48.3% (OR 1.4; 95% CI, 0.5-3.6). A total of 6.1% (RFA) and 13.3% (APC) had buried BE glands. Adverse events (including stricture rate after starting RFA 3/36 [8.3%] and APC 3/37 [8.1%]) and quality of life scores were similar, but RFA cost $27491 more per case than APC.
Conclusion: This pilot study suggests similar efficacy and safety but a cost difference favoring APC. A fully powered non-inferiority trial is appropriate to confirm these findings. (Clinical trial registration number: NCT01733719.).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gie.2018.07.031 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Hôpital Cardiologique du Haut Léveque, CHU de Bordeaux, L'Institut de RYthmologie et modelisation Cardiaque (LIRYC), Université de Bordeaux, Bordeaux, France.
Background: Achieving a durable mitral line block using radiofrequency as a part of an anatomical approach for ablation in patients with persistent atrial fibrillation or for treating peri-mitral flutter has always been challenging due to the complex anatomy of the mitral isthmus. Epicardial ablation via the coronary sinus and the vein of Marshall has been proposed to help create durable lesions. Recently, a novel lattice-tip catheter using pulsed field ablation has shown promising results for creating mitral lines, despite limited data.
View Article and Find Full Text PDFThyroid
January 2025
Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
The longest reported follow-up for thermal ablation of papillary thyroid microcarcinoma (PTMC) is 5 years. We evaluated the long-term efficacy and safety of radiofrequency ablation (RFA) in patients with low-risk PTMC with clinical follow-up of more than 10 years. In this retrospective cohort study, we included patients with low-risk PTMC who had more than 10 years of follow-up after ultrasound (US)-guided RFA (performed between May 2008 and December 2013).
View Article and Find Full Text PDFRev Cardiovasc Med
January 2025
Department of Echocardiography and Cardiology, The First People's Hospital of Changzhou, 213003 Changzhou, Jiangsu, China.
Background: This article focuses on the effect of body mass index (BMI) on cardiac structure and function in cases with non-valvular atrial fibrillation (NVAF). Only a few articles have investigated the relationship between BMI and the incidence of left atrial thrombus (LAT) or spontaneous echo contrast (SEC) in cases with NVAF.
Methods: This single-center retrospective study was conducted at The First People's Hospital of Changzhou.