Recognition of Spanish consonants in 8-talker babble by children with cochlear implants, and by children and adults with normal hearing.

J Acoust Soc Am

Departamento Lengua Española y Lingüística General, Universidad de Murcia Campus de La Merced, 30001 Murcia, Spain.

Published: July 2018

This paper presents the results of closed-set recognition task for 80 Spanish consonant-vowel sounds in 8-talker babble. Three groups of subjects participated in the study: a group of children using cochlear implants (CIs; age range: 7-13), an age-matched group of children with normal hearing (NH), and a group of adults with NH. The speech-to-noise ratios at which the participants recognized 33% of the target consonants were +7.8 dB, -3 dB, and -6 dB, respectively. In order to clarify the qualitative differences between the groups, groups were matched for the percentage of recognized syllables. As compared with the two groups with NH, the children with CIs: (1) produced few "I do not know" responses; (2) frequently selected the voiced stops (i.e., /b, d, ɡ/) and the most energetic consonants (i.e., /l, r, ʝ, s, ʧ/); (3) showed no vowel context effects; and (4) had a robust voicing bias. As compared with the adults with NH, both groups of children showed a fronting bias in place of articulation errors. The factors underlying these error patterns are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1121/1.5044416DOI Listing

Publication Analysis

Top Keywords

8-talker babble
8
children cochlear
8
cochlear implants
8
normal hearing
8
group children
8
groups children
8
children
6
groups
5
recognition spanish
4
spanish consonants
4

Similar Publications

Introduction: Contralateral routing of signals (CROS) overcomes the head shadow effect by redirecting speech signals from the contralateral ear to the better-hearing cochlear implant (CI) ear. Here we tested the performance of an adaptive monaural beamformer (MB) and a fixed binaural beamformer (BB) using the CROS system of Advanced Bionics.

Methods: In a group of 17 unilateral CI users, we evaluated the benefits of MB and BB for speech recognition by measuring speech reception threshold (SRT) with and without beamforming.

View Article and Find Full Text PDF

We have investigated the effectiveness of three noise-reduction algorithms, namely an adaptive monaural beamformer (MB), a fixed binaural beamformer (BB), and a single-microphone stationary-noise reduction algorithm (SNRA) by assessing the speech reception threshold (SRT) in a group of 15 bimodal cochlear implant users. Speech was presented frontally towards the listener and background noise was established as a homogeneous field of long-term speech-spectrum-shaped (LTSS) noise or 8-talker babble. We pursued four research questions, namely: whether the benefits of beamforming on the SRT differ between LTSS noise and 8-talker babble; whether BB is more effective than MB; whether SNRA improves the SRT in LTSS noise; and whether the SRT benefits of MB and BB are comparable to their improvement of the signal-to-noise ratio (SNR).

View Article and Find Full Text PDF

Purpose The purpose of this study was to examine (a) the psychometric functions of Mandarin speech-on-speech masking with a comparison to the psychometric properties of the English version and (b) the feasibility of using the method of adaptive tracking (MAT) to measure Mandarin speech recognition thresholds in different masker conditions using a Chinese coordinate response measure (C-CRM) speech corpus. Method The study followed the example of the English coordinate response measure (E-CRM) speech corpus and designed a Chinese version. Sixteen listeners were recruited for a monaural Mandarin speech recognition test using C-CRM materials in 5 competing speech masker conditions: 1-talker different-gender, 1-talker same-gender, and 2-, 4-, and 8-talker maskers.

View Article and Find Full Text PDF

Objective: Normal-hearing subjects listening to acoustic simulations of cochlear implants (CI) can obtain sentence recognition scores near 100% in quiet and in 10 dB signal-to-noise ratio (SNR) noise with acute exposure. However, average sentence recognition scores for real CI listeners are generally lower, even after months of experience, and there is a high degree of heterogeneity. Our aim was to identify the relative importance and strength of factors that prevent CI listeners from achieving early, 1-mo scores as high as those for normal-hearing-listener acoustic simulations.

View Article and Find Full Text PDF

Recognition of Spanish consonants in 8-talker babble by children with cochlear implants, and by children and adults with normal hearing.

J Acoust Soc Am

July 2018

Departamento Lengua Española y Lingüística General, Universidad de Murcia Campus de La Merced, 30001 Murcia, Spain.

This paper presents the results of closed-set recognition task for 80 Spanish consonant-vowel sounds in 8-talker babble. Three groups of subjects participated in the study: a group of children using cochlear implants (CIs; age range: 7-13), an age-matched group of children with normal hearing (NH), and a group of adults with NH. The speech-to-noise ratios at which the participants recognized 33% of the target consonants were +7.

View Article and Find Full Text PDF