Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare the sensitivity of detection and the measured size of choroidal neovascularization (CNV) on two commercially available spectral domain optical coherence tomography angiography (OCTA) devices, the Optovue RTVue XR Avanti with AngioVue and the Zeiss Cirrus HD-OCT with AngioPlex.
Methods: Patients with CNV lesions were imaged consecutively on both OCTA devices on the same day of their visit. 3 × 3 mm and 6 × 6 mm scans centered at the fovea were obtained. Two independent masked readers evaluated the OCTA images for CNV identification and its area measurements.
Results: No significant differences were observed between the 2 OCTA devices in CNV area measurements on their 3 × 3 mm and 6 × 6 mm scans. However, there was suboptimal performance of their automated segmentation algorithms as compared to manually adjusted segmentation for visualizing CNV lesions.
Conclusion: There was no significant difference in the size of the CNV lesion as measured on either commercially available spectral domain OCTA device. Both devices were comparable in their detection of CNV lesions on manual adjustment of segmentation lines. However, their automated segmentation algorithms need improvement to allow for accurate measurement of CNV lesions for routine clinical application.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/IAE.0000000000002241 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!