Objectives: (1) To determine the effect of hearing aid (HA) bandwidth on bimodal speech perception in a group of unilateral cochlear implant (CI) patients with diverse degrees and configurations of hearing loss in the nonimplanted ear, (2) to determine whether there are demographic and audiometric characteristics that would help to determine the appropriate HA bandwidth for a bimodal patient.
Design: Participants were 33 experienced bimodal device users with postlingual hearing loss. Twenty three of them had better speech perception with the CI than the HA (CI>HA group) and 10 had better speech perception with the HA than the CI (HA>CI group). Word recognition in sentences (AzBio sentences at +10 dB signal to noise ratio presented at 0° azimuth) and in isolation [CNC (consonant-nucleus-consonant) words] was measured in unimodal conditions [CI alone or HAWB, which indicates HA alone in the wideband (WB) condition] and in bimodal conditions (BMWB, BM2k, BM1k, and BM500) as the bandwidth of an actual HA was reduced from WB to 2 kHz, 1 kHz, and 500 Hz. Linear mixed-effect modeling was used to quantify the relationship between speech recognition and listening condition and to assess how audiometric or demographic covariates might influence this relationship in each group.
Results: For the CI>HA group, AzBio scores were significantly higher (on average) in all bimodal conditions than in the best unimodal condition (CI alone) and were highest at the BMWB condition. For CNC scores, on the other hand, there was no significant improvement over the CI-alone condition in any of the bimodal conditions. The opposite pattern was observed in the HA>CI group. CNC word scores were significantly higher in the BM2k and BMWB conditions than in the best unimodal condition (HAWB), but none of the bimodal conditions were significantly better than the best unimodal condition for AzBio sentences (and some of the restricted bandwidth conditions were actually worse). Demographic covariates did not interact significantly with bimodal outcomes, but some of the audiometric variables did. For CI>HA participants with a flatter audiometric configuration and better mid-frequency hearing, bimodal AzBio scores were significantly higher than the CI-alone score with the WB setting (BMWB) but not with other bandwidths. In contrast, CI>HA participants with more steeply sloping hearing loss and poorer mid-frequency thresholds (≥82.5 dB) had significantly higher bimodal AzBio scores in all bimodal conditions, and the BMWB did not differ significantly from the restricted bandwidth conditions. HA>CI participants with mild low-frequency hearing loss showed the highest levels of bimodal improvement over the best unimodal condition on CNC words. They were also less affected by HA bandwidth reduction compared with HA>CI participants with poorer low-frequency thresholds.
Conclusions: The pattern of bimodal performance as a function of the HA bandwidth was found to be consistent with the degree and configuration of hearing loss for both patients with CI>HA performance and for those with HA>CI performance. Our results support fitting the HA for all bimodal patients with the widest bandwidth consistent with effective audibility.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6355393 | PMC |
http://dx.doi.org/10.1097/AUD.0000000000000638 | DOI Listing |
Elife
December 2024
Centre for Cognitive Neuroscience and Department of Psychology, Paris-Lodron-University of Salzburg, Salzburg, Austria.
Phantom perceptions like tinnitus occur without any identifiable environmental or bodily source. The mechanisms and key drivers behind tinnitus are poorly understood. The dominant framework, suggesting that tinnitus results from neural hyperactivity in the auditory pathway following hearing damage, has been difficult to investigate in humans and has reached explanatory limits.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, NY, United States of America.
Objective: What we hear may influence postural control, particularly in people with vestibular hypofunction. Would hearing a moving subway destabilize people similarly to seeing the train move? We investigated how people with unilateral vestibular hypofunction and healthy controls incorporated broadband and real-recorded sounds with visual load for balance in an immersive contextual scene.
Design: Participants stood on foam placed on a force-platform, wore the HTC Vive headset, and observed an immersive subway environment.
Congenit Anom (Kyoto)
January 2025
Division of Research and Treatment for Oral and Maxillofacial Congenital Anomalies, School of Dentistry, Aichi Gakuin University, Nagoya, Japan.
Pregnancy loss is a significant concern worldwide, encompassing miscarriage and stillbirth. Miscarriage, defined as the loss of a baby before 28 weeks of gestation, accounts for approximately 15% of pregnancies. Stillbirth, occurring at or after 28 weeks of gestation, affects nearly 2.
View Article and Find Full Text PDFJ Speech Lang Hear Res
January 2025
Research Unit of Logopedics and the Child Language Research Center, University of Oulu, Finland.
Purpose: Children develop social-pragmatic understanding with the help of sensory, cognitive, and linguistic functions by interacting with other people. This study aimed to explore (a) associations between auditory, demographic, cognitive, and linguistic factors and social-pragmatic understanding in children who use bilateral hearing aids (BiHAs) or bilateral cochlear implants (BiCIs) and in typically hearing (TH) children and (b) the effect of the group (BiHA, BiCI, TH) on social-pragmatic understanding when the effects of demographic, cognitive, and linguistic factors are controlled for.
Method: The Pragma test was used to assess social-pragmatic understanding in 119 six-year-old children: 25 children who use BiHAs, 29 who use BiCIs, and 65 TH children.
J Funct Biomater
January 2025
Department of Otorhinolaryngology, Hannover Medical School, 30625 Hannover, Germany.
Cochlear implants are well established devices for treating severe hearing loss. However, due to the trauma caused by the insertion of the electrode and the subsequent formation of connective tissue, their clinical effectiveness varies. The aim of the current study was to achieve a long-term reduction in connective tissue growth and impedance by combining surface patterns on the electrode array with a poly-L-lactide coating containing 20% diclofenac.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!