A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Imaging infective endocarditis: Adherence to a diagnostic flowchart and direct comparison of imaging techniques. | LitMetric

Background: Multimodality imaging is recommended to diagnose infective endocarditis. Value of additional imaging to echocardiography in patients selected by a previously proposed flowchart has not been evaluated.

Methods: An observational single-center study was performed. Adult patients suspected of endocarditis/device infection were prospectively and consecutively enrolled from March 2016 to August 2017. Adherence to a diagnostic imaging-in-endocarditis-flowchart was evaluated in 176 patients. Imaging techniques were compared head-to-head in 46 patients receiving echocardiography (transthoracic plus transesophageal), multi-detector computed tomography angiography (MDCTA), and F-fluorodeoxyglucose positron emission tomography (FDG-PET/CT).

Results: 69% of patients (121/176) adhered to the flowchart. Sensitivity of echocardiography, MDCTA, FDG-PET/CT in patients without prosthesis was 71%, 57%, 29% (86% when combined), while specificity was 100%, 75%, 100%, respectively. Sensitivity in patients with prosthesis was 75%, 75%, 83%, respectively (100% when combined), while specificity was 86% for all three modalities. Echocardiography performed best in the assessment of vegetations, morphological valve abnormalities/dehiscence, septum defects, and fistula formation. MDCTA performed best in the assessment of abscesses and ventricular assist device infection. FDG-PET/CT performed best in the assessment of cardiac device infection, extracardiac infectious foci, and alternative diagnoses.

Conclusions: This study demonstrates that the evaluated imaging-in-endocarditis-flowchart is applicable in daily clinical practice. Echocardiography, MDCTA, and FDG-PET/CT provide relevant complementary diagnostic information, particularly in patients with intracardiac prosthetic material.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7174257PMC
http://dx.doi.org/10.1007/s12350-018-1383-8DOI Listing

Publication Analysis

Top Keywords

performed best
12
best assessment
12
infective endocarditis
8
adherence diagnostic
8
imaging techniques
8
patients
8
echocardiography mdcta
8
mdcta fdg-pet/ct
8
patients prosthesis
8
combined specificity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!