Background: Electrophysiologic studies have been considered the "gold standard" in diagnosing carpal tunnel syndrome (CTS); however, reports of false-negative results, as well as discomfort for the patient during the procedure has paved the use of ultrasound, being a painless and cost-efficient tool, as an alternative means for its diagnosis. Various ultrasound parameters assessing the median nerve and wrist dimensions have been described, but description of landmarks to assess these in a reliable manner has been lacking.

Methodology: A systematic search of different databases yielded data regarding ultrasound parameters for CTS diagnosis, the landmarks used, and presence of reliability testing. Based on this, three sonologists discussed the external and sonographic landmarks that will be used in measuring the median nerve measurements, bowing of the flexor retinaculum and the carpal tunnel dimensions. A pilot test with two consecutive healthy participants using the discussed ultrasound parameters was carried out, and results were subjected to inter- and intra-rater reliability testing. Modifications were accordingly made on the acquisition of ultrasound image using external landmarks. The reliability testing proper was done with ten consecutive healthy participants.

Results: Based on the systematic review and the pilot study, external landmarks were used to locate the median nerve in the forearm, carpal tunnel inlet and outlet. For the forearm measurement, it was taken 10 cm proximal from the distal palmar crease. The distal palmar crease was the external landmark used for the carpal tunnel inlet, while for the carpal tunnel outlet; it was measured 1 cm distal to the distal palmar crease. Instead of using the inner edge of the hook of hamate and trapezium, the apices of these bones were used as the landmarks in measuring the carpal tunnel outlet dimensions. There was excellent intra-rater reliability (mid-forearm, carpal tunnel inlet and outlet) except for the following: cross-sectional area (CSA) of the median nerve at the carpal tunnel inlet and outlet; and bowing of the flexor retinaculum. All the parameters had an excellent inter-rater reliability measured at the three levels (intraclass correlation [ICC]: Of 0.77-0.99) except for CSA of the median nerve at the levels of the forearm (fair-to-good with ICC of 0.71) and the carpal tunnel inlet (fair-to-good reliability of ICC: 0.43).

Conclusion: There was an improved inter- and intra-rater reliability when external landmarks were used instead of sonographic landmarks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6029182PMC
http://dx.doi.org/10.4103/JMU.JMU_2_17DOI Listing

Publication Analysis

Top Keywords

carpal tunnel
36
median nerve
24
tunnel inlet
20
intra-rater reliability
16
ultrasound parameters
12
reliability testing
12
external landmarks
12
inlet outlet
12
distal palmar
12
palmar crease
12

Similar Publications

Purpose: Current knowledge of complication rates after volar plating of distal radius fractures mainly relies on studies of low to moderate numbers and various implants. This study sought to find the incidence of complications leading to reoperation in a sample of distal radius fractures treated with one specific volar locking plate (VLP).

Methods: We retrospectively evaluated 1,597 distal radius fractures in 1,564 patients operated with a VLP from January 2011 to December 2017 for complications leading to a reoperation.

View Article and Find Full Text PDF

Purpose: To compare anesthesia techniques (WALANT (wide-awake anesthesia no tourniquet), locoregional anesthesia, local anesthesia with tourniquet or sedation) for carpal tunnel release (CTR).

Methods: A comprehensive literature search was conducted on PubMed, MEDLINE, Embase and the Cochrane Library up to May 2023. Two independent reviewers selected the studies and extracted the data.

View Article and Find Full Text PDF

Purpose: The objective of this study was to assess the efficacy of manual therapy, specifically using the Maitland concept, in treating carpal tunnel syndrome (CTS), and to compare its effectiveness with surgical decompression of the median nerve.

Methods: A total of 69 patients were enrolled and divided into two groups: a control group (undergoing surgery) and treatment group (receiving manual therapy). Subgroups were formed based on gender, considering factors such as grip strength.

View Article and Find Full Text PDF

Introduction/aims: Prolonged distal median motor latency (DML) may occur in carpal tunnel syndrome (CTS), potentially causing an electrodiagnostic dilemma in acquired demyelinating polyneuropathies. We aimed to demonstrate that parameter values obtained from conventional median nerve conduction studies can distinguish immune-mediated demyelination from compression-induced damage.

Methods: We retrospectively reviewed the median nerve records of 73 control individuals, 125 patients with pure CTS, 31 with CTS and diabetic distal symmetric polyneuropathy, 36 with acute inflammatory demyelinating polyneuropathy, and 23 with chronic inflammatory demyelinating polyneuropathy.

View Article and Find Full Text PDF

Aims: The prevalences of aortic stenosis (AS) and transthyretin amyloid cardiomyopathy (ATTR-CM) increase with age. Identification of occult ATTR-CM in patients with AS can help explain out-of-proportion myocardial dysfunction, aid in prognostication and prompt initiation of disease-modifying treatment. Studies have suggested that many patients referred for transcatheter aortic valve implantation (TAVI) have concomitant ATTR-CM, but some have included unverified ATTR-CM in patients with ambiguous scintigrams.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!