After the advent of the quartz crystal microbalance (QCM) technology, various QCM-based sensing systems have got certain applications in many science and technology fields and resulted in dramatic progress in these fields. The core advantage of QCM is its high mass sensitivity which leads to high accuracy and low detection limit. For a QCM, the mass sensitivity is determined by the diameter and thickness of the electrode to a certain extent when the frequency of the quartz wafer is already determined. Theoretical approximate calculation reveals that there is an optimum electrode diameter corresponding to the maximum sensitivity. This is different from the traditional opinion that the smaller the electrode, the higher the mass sensitivity. A plating experiment was carried out using 28 QCMs with different electrode diameters, and the experimental results verified the existence of the optimum diameter. This study is helpful to obtain higher mass sensitivity by optimizing electrode parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2018.2860597DOI Listing

Publication Analysis

Top Keywords

mass sensitivity
20
quartz crystal
8
crystal microbalance
8
higher mass
8
sensitivity
6
mass
5
electrode
5
exploration confirmation
4
confirmation maximum
4
maximum mass
4

Similar Publications

Background: There are multiple surgical approaches for treating symptomatic simple renal cysts (SSRCs). The natural orifice transluminal endoscopic surgery (NOTES) approach has gradually been applied as an emerging minimally invasive approach for the treatment of SSRCs. However, there are no clear indicators for selecting the NOTES approach for patients with SSRCs.

View Article and Find Full Text PDF

Hepatic cystic echinococcosis (HCE), a life-threatening liver disease, has 5 subtypes, i.e., single-cystic, polycystic, internal capsule collapse, solid mass, and calcified subtypes.

View Article and Find Full Text PDF

LC-HRMS screening procedure for the detection of 11 different classes of prohibited substances in dried urine spots for doping control purposes.

Anal Bioanal Chem

January 2025

Doping Control Laboratory, Department of Diagnostic Sciences, Ghent University, Block B, Ottergemsesteenweg 460, BE-9000, Ghent, Belgium.

Dried urine spots have recently been proposed as an alternative matrix in the anti-doping field. Drying urine may open the opportunity to limit microbial and thermal degradation of the prohibited substances during transportation to the anti-doping laboratories without the need for refrigeration or freezing. In this study, a multi-targeted initial testing procedure was developed for the determination of 237 prohibited drugs/metabolites from 11 different classes in dried urine spots.

View Article and Find Full Text PDF

This study aimed to evaluate the diagnostic accuracy of ultrasonography in assessing the response of clipped axillary lymph nodes to neoadjuvant chemotherapy. Between February 2022 and September 2023, 43 patients who underwent axillary lymph node marking for targeted axillary dissection were retrospectively analyzed. Ultrasonography parameters such as the number, size, shape, cortical thickness, hilum status, and treatment response of the clipped lymph node were assessed.

View Article and Find Full Text PDF

Microbial volatile organic compounds measured in the air of a waste sorting plant and a university by thermal desorption-gas chromatography-tandem mass spectrometry.

Environ Monit Assess

January 2025

Institut de Recherche Robert-Sauvé en Santé Et en Sécurité du Travail (IRSST), Montréal, Québec, Canada.

In recyclable waste management facilities, several contaminants, mainly bioaerosols and microorganisms, can be released and cause potential adverse health effects. Given that microbial volatile organic compounds (mVOCs) are metabolites developed by molds and since they can be considered as potential biomarkers of mold exposure, their concentrations in ambient air were monitored at a recyclable waste sorting plant (WSP) and a university campus (UC) serving as control environment for comparison. A recently developed analytical method was used for the detection of 21 selected mVOCs in real conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!