A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Advances in digital and physical anthropomorphic breast phantoms for x-ray imaging. | LitMetric

Advances in digital and physical anthropomorphic breast phantoms for x-ray imaging.

Med Phys

Division of Imaging, Diagnostics, and Software Reliability, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD, 20993, USA.

Published: October 2018

Purpose: With the advent of three-dimensional (3D) breast imaging modalities such as digital breast tomosynthesis (DBT) and dedicated breast CT (bCT), research into new anthropomorphic breast phantoms has accelerated. These breast phantoms are important for the optimization of new breast imaging systems, assessing new regulatory submissions to prove safety and effectiveness, and for developing new approaches to acceptance and constancy testing of 3D breast imaging systems. This paper provides a review of current research investigating both digital and physical breast phantom development for use in x-ray based imaging.

Methods: Two approaches for designing anthropomorphic, digital breast phantoms are discussed, procedural model-based phantom generation, where breast features are expressed using mathematical models, and patient-based generation, where breast structures from tissue specimens or patient-based breast MR or CT volumes are segmented. Following this discussion, a review of physical anthropomorphic phantoms is given, with emphasis on the advantages and disadvantages present with each approach.

Conclusions: This paper provides a summary of the state-of-the-art in anthropomorphic breast phantom development for x-ray breast imaging. The primary advantage of model-based digital phantoms is that an unlimited number of phantoms with varying size, shape, and density can be generated. Current research on model-based breast phantoms is producing more and more realistic breast models; however, they probably are not yet able to pass the so-called "fool the radiologist" visualization test. Empirical patient-based breast phantoms are typically based on clinical breast CT data and look more realistic. However, clinical breast CT images have limited spatial resolution and thus do not always portray the finer details in the breast. A number of innovative solutions have been proposed for fabricating physical anthropomorphic breast phantoms based on digital phantom models; however, a number of challenges remain, including realistic modeling of x-ray attenuation properties and accurately representing high-frequency structures within breast.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13110DOI Listing

Publication Analysis

Top Keywords

breast phantoms
24
breast
22
breast imaging
16
physical anthropomorphic
12
anthropomorphic breast
12
phantoms
9
digital physical
8
digital breast
8
imaging systems
8
breast phantom
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!