Isolation and characterization of non-O157 Shiga toxin-producing Escherichia coli (STEC) isolated from retail ground beef in Santiago, Chile.

Food Microbiol

Instituto de Nutrición y Tecnología de los Alimentos, Universidad de Chile, El Líbano 5524, Macul, Santiago, Chile.

Published: October 2018

Shiga toxin-producing Escherichia coli (STEC) is one of the main cause of foodborne disease worldwide, but isolation rates or characteristics of this bacteria from ground beef in Chile are unknown. The present study aimed to isolate and characterize non-O157 STEC from ground beef sold at retail in the city of Santiago, Chile. We analyzed 430 ground beef samples for the presence of STEC, and isolated the microorganism in 10% of samples (43/430). We obtained 56 isolates from the 43 positive samples; 55 of these (98.2%) fermented sorbitol. Most isolates (98.2%; 55/56) showed β-glucoronidase activity, and only six (10.7%; 6/56) were resistant to tellurite. Among the virulence factors studied (stx, stx, eae, and hlyA), stx was the only virulence factor in 41% of the isolates (23/56), whereas 10.7% (6/56) of isolates carried a combination of three virulence factors (stx1 + stx2 + hlyA). None of the isolates carried the gene eae. Finally, isolates were neither serogroups O157 nor "big six". In conclusion, ground beef sold in Santiago, Chile is contaminated with STEC; however, further studies are required for understanding their virulence potential.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fm.2017.10.015DOI Listing

Publication Analysis

Top Keywords

ground beef
20
santiago chile
12
shiga toxin-producing
8
toxin-producing escherichia
8
escherichia coli
8
coli stec
8
stec isolated
8
beef sold
8
107% 6/56
8
virulence factors
8

Similar Publications

Effect of Physiologically Relevant Dehydration on the Dielectric Properties of Ground Beef.

Bioelectromagnetics

January 2025

Department of Electrical and Software Engineering, University of Calgary, Calgary, Alberta, Canada.

Readily available animal tissue, such as ground beef, is a convenient material to represent the dielectric properties of biological tissue when validating microwave imaging and sensing hardware and techniques. The reliable use of these materials depends on the accurate characterization of their properties. In this work, the effect of physiologically relevant levels of dehydration on ex vivo tissue samples is quantified while controlling for variation within and between samples.

View Article and Find Full Text PDF

non-typhoidal is a major contributor to diarrheal diseases, with over 2600 serovars identified across diverse environments. In Mexico, serovars Newport and Anatum have shown a marked increase, especially in foodborne disease, posing a public health problem. We conducted a cross-sectional study from 2021 to 2023 using active epidemiological surveillance to assess contamination in ground beef and pork at butcher shops nationwide.

View Article and Find Full Text PDF

Purpose: This paper outlines the commissioning of the Varian (VMS, Varian Medical Systems, Palo Alto, CA) Universal Interstitial Cylinder (UIC) applicator set for Ir-192 HDR brachytherapy. The UIC was commissioned for use with CT and MRI and a custom phantom was designed to avoid the introduction of water-like materials into the needle guide tracks. Various marker strands were investigated to determine which allowed the most accurate reconstruction of source positions.

View Article and Find Full Text PDF

Background: Postbiotics comprise soluble compounds freed from the structure of destroyed bacteria or created by living bacteria. Such byproducts provide the host with enhanced biological function as well as specific physiological consequences. This research aims to examine the characteristics and possible health advantages of -derived postbiotics.

View Article and Find Full Text PDF

Meat product labels including information on livestock production systems are increasingly demanded, as consumers request total traceability of the products. The aim of this study was to explore the potential of visible and near-infrared spectroscopy (Vis-NIRS) to authenticate meat and fat from steers raised under different feeding systems (barley, corn, grass-fed). In total, spectra from 45 steers were collected (380-2,500 nm) on the subcutaneous fat and intact longissimus thoracis (LT) at 72 h postmortem and, after fabrication, on the frozen-thawed ground longissimus lumborum (LL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!