This paper presents an innovative approach in the portable Point-of-Care diagnostics field, the Plug-and-Power concept. In this new disposable sensor and plug-and-play reader paradigm, the energy required to perform a measurement is always available within the disposable test component. The reader unit contains all the required electronic modules to run the test, process data and display the result, but does not include any battery or power source. Instead, the disposable part acts as both the sensor and the power source. Additionally, this approach provides environmental benefits related to battery usage and disposal, as the paper-based power source has non-toxic redox chemistry that makes it eco-friendly and safe to follow the same waste stream as disposable test strips. The feasibility of this Plug-and-Power approach is demonstrated in this work with the development of a self-powered portable glucometer consisting of two parts: a test strip including a paper-based power source and a paper-based biofuel cell as a glucose sensor; and an application-specific battery-less electronic reader designed to extract the energy from the test strip, process the signal provided and show the glucose concentration on a display. The device was tested with human serum samples with glucose concentrations between 5 and 30 mM, providing quantitative results in good agreement with commercial measuring instruments. The advantages of the present approach can be extended to any kind of biosensors measuring different analytes and biological matrices, and in this way, strengthen the goals of Point-of-Care diagnostics towards laboratory decentralization, personalized medicine and improving patient compliance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2018.07.034 | DOI Listing |
J Biopharm Stat
January 2025
Merck & Co, Inc, North Wales, Pennsylvania, USA.
Randomized clinical trials (RCTs) can benefit from using Real-World Data (RWD) as a supplementary data source to enhance their analysis. An Augmented RCT combines randomized treatment and control groups with synthetic controls derived from RWD. This way, the trial can achieve less prospective enrollment, higher statistical power, and lower costs.
View Article and Find Full Text PDFLangmuir
January 2025
School of Mechanical Engineering, Shenyang University of Technology, Shenyang 110870, China.
Microscale device surface encapsulation needs to use ultrafine liquid transfer technology. This technology can transfer a liquid from a donor surface to a receptor surface in a controlled manner. However, the requirement of microscale encapsulation for liquid transfer amounts is generally at the pL level.
View Article and Find Full Text PDFUltrason Sonochem
January 2025
Department of Biotechnology, Persian Gulf Research Institute, Persian Gulf University, Bushehr, Iran. Electronic address:
Given their potential as natural substitutes for artificial additives and their health advantages, the extraction of bioactive substances like polyphenols from plant sources is becoming more and more significant. Nevertheless, it is still difficult to achieve effective extraction with minimal time and energy. In order to optimize polyphenol extraction from ripe jamun fruit pulp, including traditional and ultrasound-assisted methods, this study assessed the prediction power of response surface methodology (RSM) and adaptive neuro-fuzzy inference systems (ANFIS).
View Article and Find Full Text PDFCurr Gastroenterol Rep
January 2025
Division of Pediatric Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, Columbia University Vagelos College of Physicians and Surgeons and New York- Presbyterian Morgan Stanley Children's Hospital, 630 West 168Th Street, New York, NY, PH17-105H10032, USA.
Purpose: To propose a gastrointestinal bleeding management algorithm that incorporates an endoscopic and imaging scoring system and specifies management of vascular complication from button battery ingestion.
Recent Findings: Button batteries (BB) are found in many electronic devices and ingestions are associated with serious complications especially in cases of unwitnessed ingestions, prolonged impaction, and in children less than 5 years of age. Gastrointestinal bleeding from BB related vascular injury is rare but often rapidly fatal, with a mortality rate as high as 81%.
Sci Total Environ
January 2025
Institute of Environmental Assessment and Water Research, Spanish Research Council (IDÆA-CSIC), c/Jordi Girona 18-26, 08034 Barcelona, Spain.
The maritime transport sector poses significant air quality concerns, particularly in nearby cities. Ultrafine particles (UFP, diameter < 100 nm) are of particular concern due to their potential health impacts. This study measured particle number concentrations (PNC), size distributions (PNSD), and other pollutants including particulate matter (PM), nitrogen oxides (NO), black carbon (BC), sulfur dioxide (SO) and ozone (O), organic markers and trace elements at a major European harbor and an urban background (UB) location.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!