Optimization of dynamic pH barrage junction focusing for weakly alkaline or zwitterionic analytes in capillary electrophoresis.

J Chromatogr B Analyt Technol Biomed Life Sci

Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China; Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada. Electronic address:

Published: September 2018

Dynamic pH junction focusing prior to electrophoretic separation has been widely used for online pre-concentration of biologically important analytes, which are mostly weakly alkaline/acidic or zwitterionic species such as neurotransmitters, peptides, and proteins. A pH junction is formed when background electrolytes with different pH values are injected sequentially into the separation column of a capillary electrophoresis (CE) system. Unlike the traditional dynamic pH junction configuration with analyte molecules located in a different chemical environment to the separation background electrolyte (BGE), the pH barrage junction has a separate high pH (or low pH) region containing no analyte. Based on Simul 5 Complex simulations and experimental verification with three series of electrolyte combinations, four basic principles for pH barrage junction focusing were identified for its optimization. First, the peak shape after focusing is slightly asymmetric, but this has negligible influence on the analysis result. Second, longer length of the barrage segment is needed for complete focusing with lower concentration of the buffering species. Third, this technique is more advantageous for analytes with relatively high electrophoretic mobility in a capillary without electroosmotic flow. Fourth, provided the analyte region and pH junction buffering species are separated, this quantitative technique is compatible with both optical and mass spectrometric detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2018.07.023DOI Listing

Publication Analysis

Top Keywords

barrage junction
12
junction focusing
12
capillary electrophoresis
8
dynamic junction
8
buffering species
8
junction
7
focusing
5
optimization dynamic
4
barrage
4
dynamic barrage
4

Similar Publications

Cyanotoxins constitute a group of toxic secondary metabolites, the presence of which in any water body poses a major health risk. Moreover, advanced organisms such as edible plants exposed to these toxins, are a possible pathway for human exposure. Green analytical chemistry is demanding environmentally friendly analytical techniques.

View Article and Find Full Text PDF

A dynamic pH junction was used in capillary electrophoresis (CE-DAD) to on-line preconcentrate, separate, and determine trace amounts of sulfonamide antibiotics (SAs) in milk and yoghurt samples in this study. A sample matrix with 0.15% acetic acid and 10% methanol (MeOH) at a pH of 4.

View Article and Find Full Text PDF

A simple and sensitive method for the determination of bisphenol A and its analogues at the ng/mL level in bottled tea beverages is presented. This method utilized a dynamic pH junction to focus the analyte into a more concentrated zone, based on the electrophoretic mobility difference of analytes in the sample matrix and background electrolytes in capillary electrophoresis coupled to mass spectrometry (CE-MS). The optimised analyte focusing led to enhanced signal detection with average peak heights for five bisphenols of 53-170 folds higher than conventional injections.

View Article and Find Full Text PDF

A quantitative method was developed for the direct identity confirmation and quantification of alendronate using CE-MS combined with a pH-assisted focusing technique, dynamic pH barrage junction focusing. A pH-induced variation in electrophoretic mobility led to online focusing of alendronate at the sample/pH barrage boundary, significantly improving the detection sensitivity. In addition, the use of a flow-through microvial CE electrospray interface and the multiple reaction monitoring mode of MS further improved the specificity and quantification capability of this technology.

View Article and Find Full Text PDF

Dynamic pH barrage junction focusing in CE enables effective signal enhancement, quantitative capture efficiencies, and straightforward optimization. The method is a technical variant of dynamic pH junction focusing. CE separation with dynamic pH barrage junction focusing is compatible with both optical and mass spectrometric detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!