A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Morphology and kinematics studies of the upper extremity and its clinical application in deformity correction. | LitMetric

Morphology and kinematics studies of the upper extremity and its clinical application in deformity correction.

J Orthop Sci

Department of Orthopedic Surgery, Osaka University, Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan. Electronic address:

Published: September 2018

Morphological and kinetic studies using computer-generated bone models are helpful for determining normal articular movements and various pathological conditions of the wrist joints, forearms, and elbow joints. Previous studies consisted of kinetic analyses that were carried out by superimposing three-dimensional bone models created on a computer on the basis of CT data obtained by scanning the limbs in several different positions. We applied the techniques used in such studies and have discovered a method for carrying out surgical procedure simulations aimed at correcting upper limb deformities. In addition, we have developed a system aimed at assisting surgical procedures conducted in accordance with simulations by using patient-matched guides (patient-matched instruments, PMI) and custom-made osteosynthesis plates. Our system has allowed for accurate anatomical corrections to be carried out three-dimensionally during a simple surgical procedure. The system was clinically used in the treatment of cubitus varus as well as malunited distal radial fractures and forearm fractures. As a result, accurate correction and favorable clinical outcomes have been achieved. Together with the development of therapeutic techniques, we have also simultaneously developed the related technological system, which consists of imaging protocols aimed at reducing the amount of radiation exposure and creating statistical shape models, as well as web-based tools for communication between physicians and engineers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jos.2018.05.013DOI Listing

Publication Analysis

Top Keywords

bone models
8
surgical procedure
8
morphology kinematics
4
studies
4
kinematics studies
4
studies upper
4
upper extremity
4
extremity clinical
4
clinical application
4
application deformity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!