Deep periocular cancers can be difficult to plan and treat with radiation, given the difficulties in apposing bolus to skin, and the proximity to the retina and other optic structures. We sought to compare the combination of electrons and orthovoltage therapy (OBE) with existing modalities for these lesions. Four cases-a retro-orbital melanoma (Case 1) and basal cell carcinomas, extending across the eyelid (Case 2) or along the medial canthus (Cases 3-4)-were selected for comparison. In each case, radiotherapy plans for electron only, 70% electron and 30% orthovoltage (OBE), volumetric-modulated arc therapy (VMAT), conformal arc, and protons were compared. Dose-volume histograms for planning target volume coverage and selected organs at risk (OARs) were then calculated. The V90% coverage of the planning target volume was >98% for electrons, VMAT, conformal arc and proton plans and 90.2% and 89.5% in OBE plans for Cases 2 and 3, respectively. The retinal V80% was >98% in electron, VMAT and proton plans and 79.4%; and 87.1% in OBE and conformal arcs for Case 2 and 91.3%, 36.4%, 56.9%, 52.4% and 43.7% for Case 3 in electrons, OBE, VMAT, conformal arc and proton plans, respectively. Protons provided superior coverage, homogeneity and OAR sparing, compared with all other modalities. However, given its simplicity and widespread availability, OBE is a potential alternative treatment option for moderately deep lesions where bolus placement is difficult.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6151628 | PMC |
http://dx.doi.org/10.1093/jrr/rry045 | DOI Listing |
Technol Cancer Res Treat
January 2025
Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, PR China.
Purpose: To evaluate the impact of patient setup errors on the dosimetry and radiobiological models of intensity-modulated radiotherapy (IMRT) for esophageal cancer.
Methods And Materials: This retrospective study with 56 patients in thermoplastic mask (TM) and vacuum bag (VB) groups utilized real setup-error (RSE) data from cone-beam CT scans to generate simulated setup-error (SSE) data following a normal distribution. The SSE data were applied to simulate all treatment fractions per patient by shifting the plan isocenter and recalculating the dose.
Med Dosim
January 2025
Medical Dosimetry Program at the University of Wisconsin - La Crosse, La Crosse, WI, 54601, USA.
Sweat gland cancers, particularly eccrine sweat gland carcinomas, are rare and challenging to treat due to their aggressive nature and inconspicuous clinical presentation. Aggressive digital papillary adenocarcinoma, a rare subtype, frequently presents with delays in diagnosis, increasing the risk of metastasis and recurrence. Surgical excision remains the standard treatment, but the role of postoperative radiation therapy is not well-established due to the paucity of data.
View Article and Find Full Text PDFRadiol Phys Technol
January 2025
Department of Radiotherapy, Sri Shankara Cancer Hospital and Research Centre, 1st Cross, Shankarapuram, Basavanagui, Bengaluru, 560004, Karnataka, India.
This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.
View Article and Find Full Text PDFInt J Clin Oncol
January 2025
Department of Radiation Oncology, Kindai University Faculty of Medicine, 377-2, Ohno-Higashi, Osaka-Sayama, Osaka, Japan.
Background: The purpose of this study was to compare outcomes and adverse events between three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) in patients undergoing long-course neoadjuvant radiation therapy (NA-RT) for locally advanced rectal adenocarcinoma (LARC).
Methods: We retrospectively analyzed a total of 47 consecutive patients who received NA-RT for LARC between January 2011 and September 2022. Seven and 40 patients were diagnosed with clinical stages II and III, respectively.
Radiat Environ Biophys
January 2025
Radiation Physics, Faculty of Science, Al -Azhar University, Cairo, Egypt.
This study aimed to evaluate the dosimetric and clinical outcomes of flattening filter (FF) versus flattening filter-free (FFF) beams in head and neck cancer (HNC) patients treated with volumetric modulated arc therapy (VMAT). Twenty-four patients with 70/59.4/54 Gy dose prescribed in 33 fractions with simultaneous integrated boost treatment were retrospectively analyzed to compare treatment delivery efficiency, target coverage, sparing of organs at risk (OARs), and remaining volume at risk (RVR) in two HNC groups (nasopharyngeal and oropharyngeal).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!