A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The utility of saliva testing in the estimation of uremic toxin levels in serum. | LitMetric

The utility of saliva testing in the estimation of uremic toxin levels in serum.

Clin Chem Lab Med

Department of Bioanalysis and Drugs Analysis, Faculty of Pharmacy with the Laboratory Medicine Division, Medical University of Warsaw, Warsaw, Poland.

Published: December 2018

Background p-Cresol sulfate (pCS) and indoxyl sulfate (IS) are uremic toxins, high concentrations of which are related to renal failure progression. Saliva could become the first-line diagnostic sample of choice, especially for monitoring purposes. Recently, a method for determination of pCS and IS in saliva was developed. Since no data exist on correlations between the levels of toxins in saliva and serum, the applicability of saliva as a diagnostic material is yet to be established. Here, we present a study on the assessment of the utility of saliva testing in the estimation of uremic toxin levels in serum. Methods The study material included serum and unstimulated, fasting saliva obtained from healthy volunteers (n=26) and patients at all stages of chronic kidney diseases (CKD, n=93). The concentration of pCS and IS in saliva and serum (total and unbound fractions) was determined. The daytime variation of the toxins was studied. Results A correlation was found between pCS and IS in saliva and biological active fractions in serum (0.74; 0.81). The variation of the serum/saliva ratio during the day was negligible, with a median of 10% for pCS and 6% for IS, making saliva a reliable material for the estimation of the uremic toxins in circulation at any time of the day. Significant correlations were observed between salivary toxin levels and estimated glomerular filtration rate (pCS: -0.61; IS: -0.70) as well as significant differences in toxin levels between the stages of CKD. Conclusions Saliva could be a valuable diagnostic material for the estimation of toxin levels in circulation.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2018-0087DOI Listing

Publication Analysis

Top Keywords

toxin levels
20
estimation uremic
12
pcs saliva
12
saliva
10
utility saliva
8
saliva testing
8
testing estimation
8
uremic toxin
8
levels serum
8
uremic toxins
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!