Background: Accelerated bone loss occurs rapidly following renal transplantation due to intensive immunosuppression and persistent hyperparathyroidism. In renal transplant recipients (RTRs) due to the hyperparathyroidism the non-dominant forearm is often utilized as a peripheral measurement site for dual-energy x-ray absorptiometry (DXA) measurements. The forearm is also the site of previous created distal arteriovenous fistulas (AVF). Although AVF remain patent long after successful transplantation, there are no data available concerning their impact on radial bone DXA measurements.

Methods: In this cross-sectional study we performed DXA in 40 RTRs with preexisting distal AVF (RTRs-AVF) to assess areal bone mineral density (aBMD) differences between both forearms (three areas) and compared our findings to patients with chronic kidney disease (CKD, n = 40), pre-emptive RTRs (RTRs-pre, n = 15) and healthy volunteers (n = 20). In addition, we assessed relevant demographic, biochemical and clinical aspects.

Results: We found a marked radial asymmetry between the forearms in RTRs with preexisting AVF. The radial aBMD at the distal AVF forearm was lower compared to the contralateral forearm, resulting in significant differences for all three areas analyzed: the Rad-1/3: median (interquartile range) in g/cm2, Rad-1/3: 0.760 (0.641-0.804) vs. 0.742 (0.642, 0.794), p = 0.016; ultradistal radius, Rad-UD: 0.433 (0.392-0.507) vs. 0.420 (0.356, 0.475), p = 0.004; and total radius, Rad-total: 0.603 (0.518, 0.655) vs. 0.599 (0.504, 0.642), p = 0.001). No such asymmetries were observed in any other groups. Lower aBMD in AVF forearm subregions resulted in misclassification of osteoporosis.

Conclusions: In renal transplant recipients, a previously created distal fistula may exert a negative impact on the radial bone leading to significant site-to-site aBMD differences, which can result in diagnostic misclassifications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6061984PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0200708PLOS

Publication Analysis

Top Keywords

created distal
12
radial bone
12
renal transplant
12
transplant recipients
12
previous created
8
bone dxa
8
dxa measurements
8
impact radial
8
rtrs preexisting
8
distal avf
8

Similar Publications

Background And Objectives: The key points of a monographic vascular access (VA) consultation are an adequate preoperative assessment, as well as a correct management and optimization of waiting lists. Our main objective of present study was to evaluate the degree of exploratory-dependent concordance in outpatient clinics regarding implanted VA, between nephrology and vascular surgery.

Materials And Methods: We analyzed VA created or surgically repaired between 2021 and 2022.

View Article and Find Full Text PDF

Objective: This retrospective, single centre, comparative effectiveness study aimed to compare the long term outcomes of percutaneous arteriovenous fistulae (pAVF) and surgically created arteriovenous fistulae (sAVF) created in the proximal forearm for haemodialysis access.

Methods: Data were reviewed from a prospectively maintained database on patients who underwent pAVF or sAVF creation from September 2017 to September 2023. A total of 217 pAVFs (61 WavelinQ and 156 Ellipsys) and 158 sAVFs were analysed.

View Article and Find Full Text PDF

Estimation of the effects of hand growth on muscle activation patterns: A musculoskeletal modeling study.

J Biomech

January 2025

The Joint Department of Biomedical Engineering, the University of North Carolina at Chapel Hill, Chapel Hill, NC, United States; North Carolina State University, Raleigh, NC, United States.

Throughout childhood growth and development, both the nervous and the musculoskeletal systems undergo rapid change. The goal of this study was to examine the impact of growth-related changes in skeletal size and muscle strength on the neural control of finger force generation. By modifying an existing OpenSim hand model in accordance with pediatric anthropometric data, we created 10 distinct models representing males and females at each year of development from 6 to 10 years old.

View Article and Find Full Text PDF

This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe's optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging.

View Article and Find Full Text PDF

The relevance of the presented topic lies in the rapid growth of complications from diseases that subsequently lead to limb amputation, as well as the problem of untimely detection of ischemic tissues. The aim of the study is to determine and explain the main progressive methods of surgical treatment of obstructive diseases of vessels of different calibers that lead to circulatory disorders and tissue necrosis. The following research methods were used in the work: statistical method, bibliographic, and bibliosemantic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!