Hurricane knowledge and interpretation of forecasted error cone and wind potential graphics.

J Emerg Manag

National Research & Training Center on Blindness and Low Vision, Mississippi State University, Starkville, Mississippi.

Published: October 2018

Objective: The purpose was to examine how participants understand, interpret, and make decisions using hurricane forecast graphics.

Design: A four-part online survey was administered. Participants were provided an error cone graphic and one of three experimental potential for damaging winds graphics. Hurricane knowledge was also measured.

Subjects: Two hundred eighty-six individuals initially responded to the survey. A subset of the sample was used for analysis (N = 203, with 130 responding to questions in all four parts). The average age was 41.97 (SD 12.97) with a range from 18 to 75. The reduced sample was 56.7 percent female and 43.3 percent male.

Results: Responses were significantly different between those receiving the potential for damaging winds graphic and both other graphics. The addition of the error cone did not significantly change decision making. Perceived helpfulness of the forecast graphic increased with the addition of the track, but similarly, the addition of the error cone did not contribute significantly (means = 5.91, 7.78, 8.09). A majority of respondents answered five of the six hurricane knowledge questions correctly (62.1-79 percent). The lowest percentage knew what ingredients hurricanes needed to form (36.3 percent).

Conclusions: Track information significantly altered participants' perceptions of risk from damaging winds, but the error cone did not. Hurricane knowledge was good, with misconceptions existing regarding the effectiveness of taping windows and the meaning of the term "major hurricane." Understanding of the two forecast graphics was also good.

Download full-text PDF

Source
http://dx.doi.org/10.5055/jem.2018.0363DOI Listing

Publication Analysis

Top Keywords

error cone
20
hurricane knowledge
16
damaging winds
12
potential damaging
8
addition error
8
hurricane
5
error
5
cone
5
knowledge interpretation
4
interpretation forecasted
4

Similar Publications

Measurements of tooth size for estimating inter-arch tooth size discrepancies and inter-tooth distances, essential for orthodontic diagnosis and treatment, are primarily done using traditional methods involving plaster models and calipers. These methods are time-consuming and labor-intensive, requiring multiple steps. With advances in cone-beam computerized tomography (CBCT) and intraoral scanning technology, these processes can now be automated through computer analyses.

View Article and Find Full Text PDF

While radiation hazards induced by cone-beam computed tomography (CBCT) in image-guided radiotherapy (IGRT) can be reduced by sparse-view sampling, the image quality is inevitably degraded. We propose a deep learning-based multi-view projection synthesis (DLMPS) approach to improve the quality of sparse-view low-dose CBCT images. In the proposed DLMPS approach, linear interpolation was first applied to sparse-view projections and the projections were rearranged into sinograms; these sinograms were processed with a sinogram restoration model and then rearranged back into projections.

View Article and Find Full Text PDF

Purpose: To evaluate the impact of patient setup errors on the dosimetry and radiobiological models of intensity-modulated radiotherapy (IMRT) for esophageal cancer.

Methods And Materials: This retrospective study with 56 patients in thermoplastic mask (TM) and vacuum bag (VB) groups utilized real setup-error (RSE) data from cone-beam CT scans to generate simulated setup-error (SSE) data following a normal distribution. The SSE data were applied to simulate all treatment fractions per patient by shifting the plan isocenter and recalculating the dose.

View Article and Find Full Text PDF

Facial reconstruction, a crucial method in forensic identification, finds particular significance in cases where conventional means of identification are unavailable. This study addresses a significant gap in the field of forensic facial reconstruction focusing on facial soft tissue thickness (FSTT) and facial reconstruction techniques specifically tailored to the Thai population. By developing and implementing the 3D (three-dimensional) facial reconstruction program and compiling an extensive dataset of FSTT, this research makes substantial progress in advancing forensic facial reconstruction methodologies employing the combination Manchester Method, 3D skull images obtained through cone beam computed tomography (CBCT) scans were reconstructed using Autodesk Maya software.

View Article and Find Full Text PDF

PE-CycleGAN network based CBCT-sCT generation for nasopharyngeal carsinoma adaptive radiotherapy.

Nan Fang Yi Ke Da Xue Xue Bao

January 2025

School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.

Objectives: To explore the synthesis of high-quality CT (sCT) from cone-beam CT (CBCT) using PE-CycleGAN for adaptive radiotherapy (ART) for nasopharyngeal carcinoma.

Methods: A perception-enhanced CycleGAN model "PE-CycleGAN" was proposed, introducing dual-contrast discriminator loss, multi-perceptual generator loss, and improved U-Net structure. CBCT and CT data from 80 nasopharyngeal carcinoma patients were used as the training set, with 7 cases as the test set.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!