Drug-Coated Balloon Angioplasty for Hemodialysis Fistula Maintenance. | LitMetric

Drug-Coated Balloon Angioplasty for Hemodialysis Fistula Maintenance.

Clin J Am Soc Nephrol

Nephrology Section, Department of Medicine, Louisiana State University Medical Center, Shreveport, Louisiana.

Published: August 2018

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086701PMC
http://dx.doi.org/10.2215/CJN.07360618DOI Listing

Publication Analysis

Top Keywords

drug-coated balloon
4
balloon angioplasty
4
angioplasty hemodialysis
4
hemodialysis fistula
4
fistula maintenance
4
drug-coated
1
angioplasty
1
hemodialysis
1
fistula
1
maintenance
1

Similar Publications

Background: The impact of below-the-knee (BK) runoff after drug-coated balloon (DCB) treatment in femoropopliteal (FP) lesions has not been well investigated.

Methods: This retrospective multicenter observational study enrolled 291 consecutive patients with lower extremity artery disease who underwent endovascular therapy with DCBs for FP lesions between January 2018 and December 2021. Patients were classified into four groups based on the BK runoff.

View Article and Find Full Text PDF

Background: Drug-coated balloons (DCB) are emerging as an alternative to permanent implants for managing de novo coronary artery disease, particularly in small vessels (SVD). This sub-analysis of the PICCOLETO II study aimed to compare the performance of DCB and DES in terms of Murray's law-based quantitative flow ratio (μFR) changes between baseline, post-percutaneous coronary intervention (PCI), and follow-up.

Methods: Patients with a clinical indication for PCI were assigned to receive either Xience DES or Elutax SV/Emperor DCB.

View Article and Find Full Text PDF

Importance: Drug-coated balloon (DCB) angioplasty has emerged as an alternative to drug-eluting stent (DES) implantation for percutaneous coronary intervention (PCI) in patients with coronary in-stent restenosis (ISR) as well as de novo coronary artery disease.

Observations: DCBs are balloons coated with antiproliferative agents and excipients, whose aim is to foster favorable vessel healing after appropriate lesion preparation. By providing homogeneous antiproliferative drug delivery in the absence of permanent foreign body implantation, DCBs offer multiple advantages over DES, including preservation of vessel anatomy and function and positive vessel remodeling.

View Article and Find Full Text PDF

The Optilume drug-coated balloon (DCB) (North Plymouth, USA) is a novel treatment option for urethral stricture disease that combines mechanical dilation with localized delivery of paclitaxel, an antiproliferative drug aimed at reducing recurrence rates by inhibiting scar tissue formation. This systematic review and meta-analysis, conducted using studies published in the last 10 years up to November 2024, assessed the efficacy and safety of Optilume DCB across seven studies involving 457 patients. Key outcomes included significant reductions in symptom scores, as measured by the International Prostate Symptom Score (IPSS), and improvements in urinary flow rates (QMax).

View Article and Find Full Text PDF