Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose/objective(s): To evaluate the role of surgical clips placement in the definition of boost treatment volume.
Materials/methods: Clinical Target Volumes (CTV) were defined as: CTV Breast, CTV Quadrant (based on physical exam and pre-surgical images), CTV Boost, defined by clip plus margin (1 cm for 2 or more clips and 2 cm for 1 clip only) plus radiological changes, CTV NT (normal tissue), defined by CTV Quadrant minus CTV Boost and CTV MISS (CTV that would be outside the treatment volume), defined by CTV Boost minus CTV Quadrant.
Results: A total of 247 patients were included. Upper lateral quadrant was the most common clinical location (47.3%). The median number of clips used was three. The mean volumes were: CTV Breast:982.52 cc, CTV Boost:36.59 cc, CTV Quadrant:285.07 cc, CTV NT:210.1 cc and CTV MISS:13.57 cc. Only 50.6% (125) of the patients presented the CTV Boost completely inside the CTV Quadrant and in 47.3% (117), partially inside. Among patients with any CTV MISS, 80.3% (98) had 10% or more of CTV Boost outside the treatment volume. Regarding CTV MISS, there were no statistically significant differences between the groups with 1 clip versus 2 or more clips, nor between patients with or without reconstructive surgery. In average, the CTV Boost was 87% smaller than the CTV Quadrant. The whole quadrant irradiation would lead to unnecessary irradiation of 26% of normal breast tissue.
Conclusion: Surgical bed clipping is up most important in the definition of the boost volume irradiation to ensure precision minimizing geographical miss and optimizing surrounding normal tissue sparing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejso.2018.06.010 | DOI Listing |