Background: Tracheal aspirate is the conventional method to measure biomarkers of inflammation and oxidation from premature infants on mechanical ventilation at risk for bronchopulmonary dysplasia (BPD), but this method is invasive. Exhaled breath condensate (EBC) is a novel, non-invasive method that has been used in older populations. Nitrite, a stable metabolite of nitric oxide (NO), is elevated in inflammatory conditions. We aim to investigate the feasibility of EBC nitrite collection from ventilated premature infants and to quantify EBC nitrite in infants with and without BPD. We hypothesize that EBC nitrite correlates with TA nitrite, and that EBC nitrite in the first week of life is higher in infants who will develop BPD than those without BPD.

Methods: In a pilot prospective cohort study, TA and EBC were collected in the first week of life from mechanically ventilated premature infants. Nitrite levels were measured using chemiluminescence.

Results: EBC nitrite significantly correlated with TA nitrite (r = 0.45, p = 0.025). Of 40 infants, 33 (82.5%) developed BPD. EBC and TA nitrite levels collected in the first week of life had a higher trend in infants with BPD than those without BPD (p = 0.23 and 0.38 respectively).

Conclusions: Higher trend of EBC nitrite in the first week of life was associated with the development of BPD. Correlation of nitrite level in EBC with that in TA (conventional method) highlights the utility of EBC as an alternative, non-invasive method to measure inflammation. Further refinement of conditions and timing may optimize the predictive value of EBC nitrite.

Download full-text PDF

Source
http://dx.doi.org/10.3233/NPM-17106DOI Listing

Publication Analysis

Top Keywords

ebc nitrite
32
premature infants
16
week life
16
nitrite
14
ebc
12
exhaled breath
8
breath condensate
8
infants
8
bronchopulmonary dysplasia
8
conventional method
8

Similar Publications

In Situ Collection and SERS Detection of Nitrite in Exhalations on Facemasks Based on Wettability Differences.

ACS Sens

July 2024

State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China.

As one of the common carriers of biological information, along with human urine specimens and blood, exhaled breath condensate (EBC) carries reliable and rich information about the body's metabolism to track human physiological normal/abnormal states and environmental exposures. What is more, EBC has gained extensive attention because of the convenient and nondestructive sampling. Facemasks, which act as a physical filter barrier between human exhaled breath and inhaled substances from the external environment, are safe, noninvasive, and economic devices for direct sampling of human exhaled breath and inhaled substances.

View Article and Find Full Text PDF

A non-invasive condensation collection-ion chromatography method was established for the determination of organic acids and anions including lactic acid, formic acid, acetic acid, pyruvic acid, chloride, nitrate, nitrite, and sulfate in the exhaled breath of humans. The breath exhaled was condensed and collected using a home-made exhaled breath condensation equipment. This equipment included a disposable mouthpiece as a blow-off port, one-way valve and flow meter, cold trap, disposable condensate collection tube placed in the cold trap, and gas outlet.

View Article and Find Full Text PDF

A portable and non-invasive sensor presents an innovative way to measure inflammation biomarkers in exhaled breath condensate (EBC). This research is focused on developing a miniaturized bipolar electrochemical sensor that can be connected to a smartphone app. This device will be able to detect adding known amounts of nitrite (spikes) to a salt solution and small amounts of nitrite ions in collected real samples in EBC.

View Article and Find Full Text PDF

Biomarkers of nitrosative stress in exhaled breath condensate and serum among patients with cystic fibrosis.

Adv Med Sci

September 2023

Institute of Medical Sciences, College of Medical Sciences, University of Rzeszów, Rzeszów, Poland; Department of Allergology and Cystic Fibrosis, State Hospital 2 in Rzeszow, Rzeszów, Poland.

Purpose: The measurement of biomarkers in exhaled breath condensate (EBC) offers a non-invasive way to assess airway disease and can be easily done in a clinical setting among patients with cystic fibrosis (CF). The role of oxidative and nitrosative stress in the complex pathophysiology of CF is widely accepted and biomarkers of oxidative and nitrosative stress can be measured in the serum and EBC. To our knowledge, this is the first study to assess markers of nitrosative stress in EBC and serum, collected simultaneously from the CF patients.

View Article and Find Full Text PDF

In this work, we studied several important parameters regarding the standardization of a portable sensor of nitrite, a key biomarker of inflammation in the respiratory tract in untreated EBC samples. The storage of the EBC samples and electrical properties of both EBC samples and the sensor as main standardization parameters were investigated. The sensor performance was performed using differential pulse voltammetry (DPV) in a standard nitrite solution and untreated EBC samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!