Rotating hinge knee causes lower bone-implant interface stress compared to constrained condylar knee replacement.

Knee Surg Sports Traumatol Arthrosc

Head of Gluskin Granovsky, Division of Orthopedic Surgery, Mount Sinai Hospital, University of Toronto, 600 University Avenue, Toronto, ON, M5G 1X5, Canada.

Published: April 2019

Purpose: To compare the stresses at bone-arthroplasty interface of constrained and semi-constrained knee prostheses, using the finite element (FE) method as a predictor of the survivorship of the implants.

Methods: Three-dimensional FE models of the knee implanted with rotating hinge (RHK) and legacy constrained condylar (LCCK) prostheses were generated to study the loads and stresses for two situations: medial- and lateral collateral ligament deficiencies in full extension.

Results: On average, the shear stress developed at bone-implant interface dropped from 16.9 to 13.7 MPa (18.9%), and the interface von Mises stress lowered from 37.6 to 30.2 MPa (19.6%) in RHK compared to those in LCCK prostheses. RHK design also resulted in a more uniform stress distribution at the interfaces in both femur and tibia. The average polyethylene liner stress dropped from 9.6 to 2.6 MPa (a 72.7% decrease) in RHK design when compared to that in LCCK design.

Conclusion: The more uniform interface stress suggests fewer density changes at the periprosthetic regions due to bone remodelling. Moreover, the lower polyethylene stresses are likely to reduce wear and damage. These findings reveal that the RHK design may have more favorable mechanical features compared to LCCK design in full extension boundary conditions, implying a potentially better survivorship. However, the findings should be interpreted cautiously as other configurations were not investigated.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-018-5054-8DOI Listing

Publication Analysis

Top Keywords

compared lcck
12
rhk design
12
rotating hinge
8
bone-implant interface
8
interface stress
8
constrained condylar
8
lcck prostheses
8
stress
6
interface
5
rhk
5

Similar Publications

Article Synopsis
  • Asymmetric tibial components in total knee arthroplasty (TKA) were evaluated against symmetric components to assess bony coverage in cases with simulated bone defects using CT scans from 45 patients.
  • The study examined three models (PCCK, NexGen LCCK, and ATTUNE) with varying thickness augmentations to simulate defects of 5, 10, and 15 mm, measuring coverage, overhang, and underhang rates.
  • Results indicated that asymmetric components (PCCK) provided better overall coverage and reduced both anterior overhang and posterior underhang compared to symmetric components, potentially leading to improved long-term outcomes for patients.
View Article and Find Full Text PDF

Background: Aims of this study were to compare the functional and radiographic results, perioperative complication after lateral unicompartmental knee arthroplasty (LUKA) with total knee arthroplasty (TKA) and the legacy constrained condylar knee (LCCK) arthroplasty for the treatment of lateral compartmental knee osteoarthritis (LCKOA), and to provide a basis for the treatment of LCKOA.

Methods: From January 2021 to January 2024, analyzed retrospectively clinical data of 74 patients with LCKOA treated with LUKA, TKA and LCCK arthroplasty. According to the operation plan, the patients were divided into three groups: LUKA group (23 cases), TKA group (23 cases) and LCCK group (28 cases).

View Article and Find Full Text PDF

Purpose: This retrospective study aimed to assess the effects of two differing revision total knee implants designs (condylar and rotating hinge) on joint line height.

Method: The use of distal augmentation and pre and post revision radiographic joint line heights were compared in 19 condylar type knee replacements (Zimmer NexGen Legacy Constrained Condylar Knee - LCCK) and 40 LINK-Endo-rotating hinge knee replacements. Joint line and patellar heights were determined for each implant using four validated methods.

View Article and Find Full Text PDF

Long-term results (after a mean 11.3years, and up to 22years, of follow-up) of the Legacy Constrained Condylar Knee (LCCK™) in primary total knee arthroplasty.

Orthop Traumatol Surg Res

May 2024

Université de Lille, Hauts-de-France, 59000 Lille, France; Service d'orthopédie II, hôpital Roger-Salengro, CHU de Lille, place de Verdun, 59000 Lille, France.

Introduction: The use of a sliding prosthesis in total knee arthroplasty (TKA) with increased stress is an intermediate solution in primary surgery, between posteriorly stabilized prostheses and hinged prostheses, in cases of ligamentous laxity and/or loss of bone substance. Favorable results have been reported in the medium term but to our knowledge, this type of prosthesis has not been evaluated in Europe beyond 10 years of follow-up. We therefore conducted a retrospective study in order to carry out: 1) the study of the survival of the Legacy Constrained Condylar Knee (LCCK™) prosthesis in primary surgery, 2) the analysis of complications, functional scores and radiographic data, 3) the analysis of the link between the diaphyseal filling rate and prosthetic loosening.

View Article and Find Full Text PDF

Is a greater degree of constraint really harmful? Clinical biomechanical comparative study between condylar constrained knee and rotating hinge prosthesis.

Clin Biomech (Bristol)

January 2024

Gregorio Marañón General Hospital, C/ Doctor Esquerdo 46, 28007, Madrid, Spain; Surgery Department, Faculty of Medicine, Complutense University of Madrid, Plaza Ramón y Cajal s/n, 28040, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Calle Dr. Esquerdo, 46, 28007, Madrid, Spain.

Article Synopsis
  • The study compares the tibial rotation between two types of knee implants: rotating hinge knee prostheses and constrained condylar prostheses, focusing on clinical outcomes in revision knee arthroplasty.
  • It included 20 patients, with 10 receiving each type of prosthesis, and tibial rotation was measured at various degrees of knee flexion using accelerometers.
  • Results showed that the rotating hinge knee group had significantly higher tibial rotation and better postoperative Knee Injury and Osteoarthritis Outcome Scores, suggesting it may offer greater clinical satisfaction due to its lower rotational constraint.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!