A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The POST trial: initial post-market experience of the Penumbra system: revascularization of large vessel occlusion in acute ischemic stroke in the United States and Europe. | LitMetric

Background And Purpose: The purpose of this study was to assess the initial post-market experience of the device and how it is compared with the Penumbra Pivotal trial used to support the 510k application.

Methods: A retrospective case review of 157 consecutive patients treated with the Penumbra system at seven international centers was performed. Primary endpoints were revascularization of the target vessel (TIMI score of 2 or 3), good functional outcome as defined by a modified Rankin scale (mRS) score of ≤2 and incidence of procedural serious adverse events. Results were compared with those of the Penumbra pivotal trial.

Results: A total of 157 vessels were treated. Mean baseline values at enrollment were: age 65 years, NIHSS score 16. After use of the Penumbra system, 87% of the treated vessels were revascularized to TIMI 2 (54%) or 3 (33%) as compared with 82% reported in the Pivotal trial. Nine procedural serious adverse events were reported in 157 patients (5.7%). All-cause mortality was 20% (32/157), and 41% had a mRS of ≤2 at 90-day follow-up as compared with only 25% in the Pivotal trial. Patients who were successfully revascularized by the Penumbra system had significantly better outcomes than those who were not.

Conclusion: Initial post-market experience of the Penumbra system revealed that the revascularization rate and safety profile of the device are comparable to those reported in the Pivotal trial. However, the proportion of patients who had good functional outcome was higher than expected.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jnis.2010.002600.repDOI Listing

Publication Analysis

Top Keywords

penumbra system
20
pivotal trial
16
initial post-market
12
post-market experience
12
experience penumbra
8
compared penumbra
8
penumbra pivotal
8
good functional
8
functional outcome
8
procedural serious
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!