A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimization of parameters for femoral component implantation during TKA using finite element analysis and orthogonal array testing. | LitMetric

Background: Individualized and accurate implantation of a femoral component during total knee arthroplasty (TKA) is essential in achieving equal distribution of intra-articular stress and long-term survival of the prosthesis. However, individualized component implantation remains challenging. This study aimed to optimize and individualize the positioning parameters of a femoral component in order to facilitate its accurate implantation.

Methods: Using computer-simulated TKA, the positioning parameters of a femoral component were optimized individually by finite element analysis in combination with orthogonal array testing. Flexion angle, valgus angle, and external rotation angle were optimized in order to reduce the peak value of the pressure on the polyethylene liner of the prosthesis.

Results: The optimal implantation parameters of the femoral component were as follows: 1° flexion, 5° valgus angle, and 4° external rotation. Under these conditions, the peak value of the pressure on the polyethylene liner surface was minimized to 16.46 MPa. Among the three parameters, the external rotation angle had the greatest effect on the pressure, followed by the valgus angle and the flexion angle.

Conclusion: Finite element analysis in combination with orthogonal array testing can optimize the implantation parameters of a femoral component for TKA. This approach would possibly reduce the wear of the polyethylene liner and prolong the survival of the TKA prosthesis, due to its capacity to minimize stress. This technique represents a new method for preoperative optimization of the implantation parameters that can achieve the best possible TKA outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6053797PMC
http://dx.doi.org/10.1186/s13018-018-0891-1DOI Listing

Publication Analysis

Top Keywords

femoral component
24
parameters femoral
20
finite element
12
element analysis
12
orthogonal array
12
array testing
12
valgus angle
12
external rotation
12
polyethylene liner
12
implantation parameters