A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Temperature-dependent schlieren effect in liquid flow for chemical analysis. | LitMetric

Temperature-dependent schlieren effect in liquid flow for chemical analysis.

Talanta

Flow Innovation-Research for Science and Technology Laboratories (FIRSTLabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok 10400, Thailand. Electronic address:

Published: October 2018

In flow analysis, such as flow injection analysis, liquid lens is formed at the boundary between two adjacent liquid media which have different refractive indices. Light refraction at the liquid interface gives the so-called 'schlieren signal'. Schlieren effect is both concentration-dependent and temperature-dependent. In this work, the schlieren signal from temperature difference was quantitatively investigated for application in enthalpimetric measurement. The schlieren phenomena was then exploited for chemical analysis. A thermal insulated single flow line manifold was constructed using deionized water at 23 °C as the carrier. Deionized water at various temperatures in the range of 5-85 °C was injected into the carrier flow. A correlation between the schlieren signal and sample temperature was observed. A heat exchanger unit (HEU), consisting of a small volume glass-reaction chamber with a surrounding water jacket, was constructed. The unit was thermally insulated in a double layer cylindrical PVC unit. For demonstrating the applicability of temperature-dependent schlieren effect in chemical analysis, the exothermic oxidation reaction between acid dichromate and ethanol or ascorbic acid was employed with heat transferring to the surrounding water layer. When an aliquot of water from the HEU is injected into the constant temperature flow line the observed schlieren signal was dependent on the analyte concentration. Linear calibration (r > 0.99) were obtained covering the concentration range of ethanol and ascorbic acid as found in samples. The developed flow system provides good precision (RSD < 5%) with sample throughput of 4 sample h. The system were applied to the determination of ethanol in Thai white spirit and ascorbic acid in vitamin C tablets, respectively. The quantitative results obtained from the schlieren method were in agreement with the comparative methods.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2018.05.055DOI Listing

Publication Analysis

Top Keywords

chemical analysis
12
schlieren signal
12
temperature-dependent schlieren
8
analysis flow
8
deionized water
8
surrounding water
8
ethanol ascorbic
8
ascorbic acid
8
flow
7
schlieren
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!