A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Lipoma removal using a high-frequency ultrasound-guided injection of a Class III CE-marked device-Empirical findings. | LitMetric

Lipoma removal using a high-frequency ultrasound-guided injection of a Class III CE-marked device-Empirical findings.

J Cosmet Dermatol

1st Department of General and Vascular Surgery, II Medical Faculty, Medical University of Warsaw, Warsaw, Poland.

Published: April 2019

Background: Lipomas are very common benign neoplasms, which constitute 99% of all adipose-derived tumors. Main treatment option includes surgical excision, which is unacceptable for a number of patients seeking ways to improve esthetic appearance of their skin. Therefore, alternative treatment options are being sought.

Objective: The aim of the present study was to assess the efficacy of lipoma removal using a Class III CE-marked device (Aqualyx™) administered as a high-frequency ultrasound-guided injection (intralipotherapy).

Methods: A total of 17 lipomas were treated. The procedure involved a high-frequency ultrasound-guided injection. A maximum of 3 injections per a lipoma were performed. High-frequency ultrasound was used for assessing the size of lipomas and monitoring treatment-induced changes to the lipomas and adjacent tissue.

Results: Response to treatment was achieved in all cases. A complete removal was achieved in 70.59% of lipomas. The remaining 29.41% of lipomas were not completely removed, yet significantly reduced in size.

Conclusion: An injection of Aqualyx™, a CE-marked drug, is a good noninvasive treatment of lipomas. Ultrasound guided procedure is recommended, as it ensures appropriate technique and enables monitoring treatment-induced changes. Considering a low number of published reports of such treatment, it is crucial to continue this research.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocd.12681DOI Listing

Publication Analysis

Top Keywords

high-frequency ultrasound-guided
12
ultrasound-guided injection
12
lipoma removal
8
class iii
8
iii ce-marked
8
monitoring treatment-induced
8
treatment-induced changes
8
lipomas
7
treatment
5
high-frequency
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!