Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Ultrasound (US)-guided peripheral IVs have a high failure rate. We explore the relationship between the quantity of catheter residing within the vein and the functionality of the catheter over time.
Methods: This was a prospective, observational single-site study. Adult ED patients with US-guided IVs had the catheter visualised under ultrasound post-placement. IV placement time and catheter length residing in the vein was obtained. Exclusions included catheter not visualised, patient discharged from ED unless IV failed, <24 hour hospitalisation unless IV failed or patient self-removed IV.Inpatient follow-up occurred within 24, 48 and 72 hours from the IV placement time. Catheter functionality was noted. If the catheter failed, the time and reason for failure was documented.
Results: 113 patients were enrolled; 27 were excluded. Of the 86 study subjects, 29 (33.7%) patients' IVs failed and 57 (66.3%) remained functional. Median time to IV failure was 15.6 hours. 100% of IVs failed when <30% of the catheter was in the vein; 32.4% of IVs failed when 30%-64% of the catheter was in the vein; no IVs failed when ≥65% of the catheter was in the vein (p<0.0002). The HR was 0.71 (95% CI 0.60 to 0.83), and for every 5% increase of catheter in vein, the hazard of the IV failing decreases by 29% (p<0.0001).
Conclusion: The quantity of catheter residing in the vein is a key predictor of long-term functionality of US-guided IVs and is strongly associated with the hazard of failure within 72 hours. Catheter failure is high when <30% of the catheter resided in the vein. Optimum catheter survival occurs when ≥65% of the catheter is placed in the vein.