In a surgical operation requiring endoscopy, it is essential to obtain a clear endoscopic view. However, it is often disturbed by the contamination on the lens during the surgery. No device can clean the lens surface simply and completely. Many surgeons are hampered by the impaired view and the distraction by the repeated cleaning of the lens. Therefore, we developed a novel endoscope cleaning device to address this problem. The device was made of 3D-printed rubber-like plastic. It contains a syringe filled with saline and an aspiration system. It would be used intraoperatively to wash the lens surface in a few seconds with rapid flow of water and air. The cleaning ability of the device was evaluated using mayonnaise with adenosine triphosphate (ATP) as a model contaminant. The gauze-wiping maneuver was selected as control. After each maneuver, the clarity of the endoscopic view was evaluated, and residual contaminants were assessed quantitatively with ATP assay. The cleaning device obtained a crisp and clear view and eliminated the contaminant on the lens every time after a single cleaning maneuver. The gauze-wiping maneuver required for the lens to be wiped at least three times to obtain a clear view, and even then, some contaminants remained. Repeated contamination and cleaning using gauze led to accumulation of contaminants on the lens, which resulted in difficulty in cleaning the lens as the operation proceeded. The cleaning device did not show such accumulation. Our novel cleaning device with air and water flow has been shown to wash out the lens contaminants completely and immediately in a simple manner. It is expected to improve the safety and cost-effectiveness of endoscopic surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6051665 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0200749 | PLOS |
Acta Odontol Scand
January 2025
Private Practice, Kristianstad, Sweden.
Aims: Little attention has been paid to patients' perception of function and esthetics with single dental implants. The aim of this study was therefore to describe patient-reported function and esthetic outcomes in single dental implants. A second aim was to study the objective esthetics in single dental implants.
View Article and Find Full Text PDFSci Rep
January 2025
First Hospital of China Medical University, Shenyang, China.
The highest unqualified cleaning rate of suction-type lumen instruments is a major challenge for a central sterile supply department (CSSD). However, A few comprehensive studies have analyzed the main factors affecting cleaning quality. In response, this study aimed to explore the current state and the factors affecting the cleaning quality of reused suction-type metal lumen instruments in CSSD.
View Article and Find Full Text PDFiScience
January 2025
School of Physics and Electronics, Shandong Normal University, Jinan 250358, China.
The quantum anomalous Hall effect (QAHE) demonstrates the potential for achieving quantized Hall resistance without the need for an external magnetic field, making it highly promising for reducing energy loss in electronic devices. Its realization and research rely heavily on precise first-principles calculations, which are essential for analyzing the electronic structures and topological properties of novel two-dimensional (2D) materials. This review article explores the theoretical progress of QAHE in 2D hexagonal monolayers with strong spin-orbit coupling and internal magnetic ordering.
View Article and Find Full Text PDFExpert Rev Med Devices
January 2025
Faculty of Pharmacy, VNS Group of Institutions, Bhopal, Madhya Pradesh, India.
Background: Cardiac stents are utilized to treat coronary artery diseases, a leading cause of death worldwide including in India. We investigated frequency and nature of adverse events (AEs) associated with cardiac stents in the Indian population.
Methods: The source data was systematically collected by National Coordination Centre -Materiovigilance programme of India (NCC-MvPI), anonymized from 2020 to 2022.
J Dent
January 2025
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China. Electronic address:
Objectives: Highly translucent yttria-stabilized zirconia (YSZ) has become more popular due to its enhanced aesthetics. This study aimed to evaluate the influence of traditional air abrasion and a new etching and cleaning agent, Multi Etchant, on the mechanical performance, optical properties, and bond strength of highly translucent zirconia.
Methods: Specimens of 6YSZ, 5YSZ, 4YSZ&5YSZ, and conventional 3YSZ were fabricated and underwent different surface treatments, including as milled, air abrasion, and Multi Etchant.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!