Many sensory systems are tuned to specific parameters of behaviors and have effects that are task-specific. We have studied how force feedback contributes to activation of synergist muscles in serially homologous legs of stick insects. Forces were applied using conventional half-sine or ramp and hold functions. We also utilized waveforms of joint torques calculated from experiments in freely walking animals. In all legs, forces applied to either the tarsus (foot) or proximal leg segment (trochanter) activated synergist muscles that generate substrate grip and support, but coupling of the depressor muscle to tarsal forces was weak in the front legs. Activation of trochanteral receptors using ramp and hold functions generated positive feedback to the depressor muscle in all legs when animals were induced to seek substrate grip. However, discharges of the synergist flexor muscle showed adaptation at moderate force levels. In contrast, application of forces using torque waveforms, which do not have a static hold phase, produced sustained discharges in muscle synergies with little adaptation. Firing frequencies reflected the magnitude of ground reaction forces, were graded to changes in force amplitude, and could also be modulated by transient force perturbations added to the waveforms. Comparison of synergist activation by torques and ramp and hold functions revealed a strong influence of force dynamics (dF/d t). These studies support the idea that force receptors can act to tune muscle synergies synchronously to the range of force magnitudes and dynamics that occur in each leg according to their specific use in behavior. NEW & NOTEWORTHY The effects of force receptors (campaniform sensilla) on leg muscles and synergies were characterized in stick insects using both ramp and hold functions and waveforms of joint torques calculated by inverse dynamics. Motor responses were sustained and showed reduced adaptation to the more "natural" and nonlinear torque stimuli. Calculation of the first derivative (dF/d t) of the torque waveforms demonstrated that this difference was correlated with the dynamic sensitivities of the system.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6230780 | PMC |
http://dx.doi.org/10.1152/jn.00371.2018 | DOI Listing |
Clin Biomech (Bristol)
January 2025
Department of Mechanical Engineering, University of Michigan, 2350 Hayward St, Ann Arbor, MI 48109, United States; Department of Biomedical Engineering, University of Michigan, 200 Bonisteel Blvd, Ann Arbor, MI 48109, United States. Electronic address:
Background: The lower birth canal is the final constriction through which a fetal head must pass for delivery. Unfortunately, injuries to the lower birth canal tissues occur in up to 19 % of first-time vaginal deliveries due to the 300 % stretch required.
Methods: This is a secondary analysis of data from 56 healthy nullipara recorded by a lower birth canal dilator during the first stage of labor.
Arch Orthop Trauma Surg
December 2024
Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland.
Introduction: According to current clinical practice, a minimum of 7 knots are required to provide secure hold in high-strength sutures. A new technology featuring a suture tape with a salt-infused silicon core has been recently developed, potentially reducing the number of needed knots.
Aims: to (1) assess the influence of number of knots on tape security, (2) evaluate the effect of different ambient conditions on knot security, and (3) compare the biomechanical competence of the novel versus a conventional suture tape.
J Neurophysiol
December 2024
School of Kinesiology, Faculty of Health Sciences, The University of Western Ontario, London, Ontario, Canada.
The purpose of this study was to test whether inducing postactivation potentiation (PAP) altered motor unit (MU) activity during dynamic isotonic contractions. From 12 participants (3 females), 39 MUs were recorded from the anconeus ( = 31) and lateral triceps brachii ( = 8) with fine-wire electrodes during elbow extensions at 50% and 75% of peak power with, and without PAP. To induce PAP, participants produced a 2-s ramp conditioning contraction (CC) up to maximal isometric elbow extension with a 3-s hold.
View Article and Find Full Text PDFRespir Res
October 2024
Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Dresden, Germany.
Background: Subject-ventilator asynchrony (SVA) was shown to be associated with negative clinical outcomes. To elucidate pathophysiology pathways and effects of SVA on lung tissue histology a reproducible animal model of artificially induced asynchrony was developed and evaluated.
Methods: Alterations in ventilator parameters were used to induce the three main types of asynchrony: ineffective efforts (IE), auto-triggering (AT), and double-triggering (DT).
Sci Rep
September 2024
Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand.
Real-time reverse transcription polymerase chain reaction (RT-PCR), a standard method recommended for the diagnosis of coronavirus disease 2019 (COVID-19) requires 2-4 h to get the result. Although antigen test kit (ATK) is used for COVID-19 screening within 15-30 min, the drawback is its limited sensitivity. Hence, a rapid one-step quadruplex real-time RT-PCR assay: termed ƩS COVID-19 targeting ORF1ab, ORF3a, and N genes of SARS-CoV-2; and Avocado sunblotch viroid (ASBVd) as an internal control was developed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!