Background: F-Fluorodeoxyglucose (FDG) positron-emission tomography/computed tomography (PET/CT) was recently introduced as a new tool for the diagnosis of prosthetic heart valve endocarditis (PVE). Previous studies reporting a modest diagnostic accuracy may have been hampered by unstandardized image acquisition and assessment, and several confounders, as well. The aim of this study was to improve the diagnostic performance of FDG PET/CT in patients in whom PVE was suspected by identifying and excluding possible confounders, using both visual and standardized quantitative assessments.

Methods: In this multicenter study, 160 patients with a prosthetic heart valve (median age, 62 years [43-73]; 68% male; 82 mechanical valves; 62 biological; 9 transcatheter aortic valve replacements; 7 other) who underwent FDG PET/CT for suspicion of PVE, and 77 patients with a PV (median age, 73 years [65-77]; 71% male; 26 mechanical valves; 45 biological; 6 transcatheter aortic valve replacements) who underwent FDG PET/CT for other indications (negative control group), were retrospectively included. Their scans were reassessed by 2 independent observers blinded to all clinical data, both visually and quantitatively on available European Association of Nuclear Medicine Research Ltd-standardized reconstructions. Confounders were identified by use of a logistic regression model and subsequently excluded.

Results: Visual assessment of FDG PET/CT had a sensitivity/specificity/positive predictive value/negative predictive value for PVE of 74%/91%/89%/78%, respectively. Low inflammatory activity (C-reactive protein <40 mg/L) at the time of imaging and use of surgical adhesives during prosthetic heart valve implantation were significant confounders, whereas recent valve implantation was not. After the exclusion of patients with significant confounders, diagnostic performance values of the visual assessment increased to 91%/95%/95%/91%. As a semiquantitative measure of FDG uptake, a European Association of Nuclear Medicine Research Ltd-standardized uptake value ratio of ≥2.0 was a 100% sensitive and 91% specific predictor of PVE.

Conclusions: Both visual and quantitative assessments of FDG PET/CT have a high diagnostic accuracy in patients in whom PVE is suspected. FDG PET/CT should be implemented early in the diagnostic workup to prevent the negative confounding effects of low inflammatory activity (eg, attributable to prolonged antibiotic therapy). Recent valve implantation was not a significant predictor of false-positive interpretations, but surgical adhesives used during implantation were.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.118.035032DOI Listing

Publication Analysis

Top Keywords

fdg pet/ct
16
prosthetic heart
12
heart valve
12
diagnostic performance
8
positron-emission tomography/computed
8
tomography/computed tomography
8
valve endocarditis
8
median age
8
age years
8
male mechanical
8

Similar Publications

Characterization of Cutaneous Radiation Syndrome in a Mouse Model Using [18F]F- Fluorodeoxyglucose Positron Emission Tomography.

Health Phys

January 2025

Nuclear Medicine and Molecular Imaging Sciences Program, Department of Clinical & Diagnostic Sciences, School of Health Professions, University of Alabama at Birmingham, Birmingham, AL.

Ionizing radiation on the skin has the potential to cause various sequelae affecting quality of life and even leading to death due to multi-system failure. The development of radiation dermatitis is attributed to oxidative damage to the skin's basal layer and alterations in immune response, leading to inflammation. Past studies have shown that [18F]F-2-fluoro-2-deoxyglucose positron emission tomography-computed tomography ([18F]F-FDG PET/CT) can be used effectively for the detection of inflammatory activity, especially in conditions like hidradenitis suppurativa, psoriasis, and early atherosclerosis.

View Article and Find Full Text PDF

Objective: To evaluate the diagnostic accuracy of 18F-FDG-PET/CT compared to conventional imaging modalities (CIM) to detect recurrence of primary salivary gland cancers (SGCs).

Data Sources: Review performed on December 26, 2024, using Embase, CINHAL, MEDLINE, and PubMed.

Review Methods: Two blinded reviewers selected studies reporting diagnostic accuracy of PET/CT in identifying locoregional recurrence and/or metastasis in patients with SGCs.

View Article and Find Full Text PDF

Extragonadal choriocarcinoma in men is an extremely rare and highly aggressive malignancy. Inconclusive biopsies due to a high necrotic component often delay diagnosis. Here is such a case, in which suggestive imaging findings on [F]FDG PET/CT, a raised level of serum β-human chorionic gonadotropin, and gynecomastia clinched the diagnosis.

View Article and Find Full Text PDF

Effectiveness of Data-Driven Gating FDG PET/CT for Abdominal Region.

J Nucl Med Technol

January 2025

Department of Nuclear Medicine, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo, Japan.

This study aimed to validate the effectiveness of MotionFree (MF) in the abdominal region using 2 different PET/CT scanners to determine how to use MF efficiently. All 198 patients underwent respiratory-gated F-FDG PET/CT with MF. Imaging was performed using Discovery MI (DMI) and Discovery IQ (DIQ) PET/CT scanners, and all data were divided into 2 groups in each category (abdominal: upper and lower abdomen, lesion size, <20 mm and ≥20 mm; scanner group: DMI and DIQ).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!