Hypothesis: Methods for cochlear coverage determination vary in their accuracy and are hence not equally reliable.
Background: The audiological outcome after cochlear implantation is known to depend on several factors. One factor shown to positively correlate with speech perception is the insertion angle. This parameter is one of the ways to describe the fraction of the cochlea spiral exposed to electric stimulation after implantation, also known as cochlear coverage, which itself is dependent on the length and type of electrode array as well as the size and shape of the implanted cochlea. While the assessment of cochlear coverage as the insertion angle is quick and uncomplicated, the accuracy of representing the relative fraction of the cochlea exposed to electric stimulation by this single measurement value remains unknown.
Methods: Both the cochlea spiral and implanted electrode array of N = 10 cochlear implant patients were traced within clinical imaging data and processed to derive the respective cochlear coverage values. These values were compared to ones derived with alternative measures like the insertion angle as well as other methods to yield the accuracy and reliability of these approaches.
Results: The insertion angle as well as two novel approaches were found to be superior to all other analyzed assessment options and well suited for clinical cochlear coverage evaluations.
Conclusion: Insertion angle measurements are well suited for cochlear coverage determination, especially regarding retrospective analyses. Prospective studies independent of anatomical irregularities should be performed with the newly proposed approaches.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAO.0000000000001904 | DOI Listing |
Children (Basel)
December 2024
Department of Audiology, Otology, Neurotology & Cochlear Implant Unit, Athens Pediatric Center, 15125 Athens, Greece.
Neonatal hearing screening (NHS) is a critical public health measure for early identification of hearing loss, ensuring timely access to interventions that can dramatically improve a child's language development, cognitive abilities, and social inclusion. Beyond clinical benefits, NHS provides long-term advantages in education and quality of life. Given that congenital hearing loss affects approximately 1-2 in every 1000 newborns worldwide, the case for universal screening is clear.
View Article and Find Full Text PDFClin Exp Otorhinolaryngol
December 2024
King Abdullah Ear Specialist Center (KAESC), King Saud Medical City, King Saud University, Riyadh 11411, Saudi Arabia.
Objectives: This experimental study compares the precision and surgical outcomes of manual versus robotic electrode insertions in cochlear implantation.
Methods: Conducted on formalin-fixed cadaveric heads, the study involved nine senior neurotologists performing both manual and robotic insertions.
Results: The results showed no statistically significant difference between the two methods in insertion angle, cochlear coverage, or electrode coverage.
Eur Arch Otorhinolaryngol
December 2024
Department for Otorhinolaryngology, University Hospital, Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, Munich, Germany.
Purpose: Individualized cochlear implantation (CI) is essential to facilitate optimal hearing results for patients. Influence of cochlear coverage (CC) has been studied, however without consideration of different CI-categories, like single sided deafness (SSD), bimodal, and bilateral separately.
Methods: Retrospective analysis of preoperative CT scans was performed at a tertiary center.
Med Biol Eng Comput
December 2024
Department of Applied Physics III, Universidad de Sevilla, Camino de los Descubrimientos, S/N, 41092, Sevilla, Spain.
Neural electrostimulation has enabled different therapies to treat a number of health problems. For example, the cochlear implant allows for recovering the hearing function and deep brain electrostimulation has been proved to reduce tremor in Parkinson's disease. Other approaches such as retinal prostheses are progressing rapidly, as researchers continue to investigate new strategies to activate targeted neurons more precisely.
View Article and Find Full Text PDFChildren (Basel)
October 2024
Department of Theoretical and Applied Sciences Applied Physics, eCampus University, 00182 Rome, Italy.
The reported data on European universal neonatal hearing screening (UNHS) practices tend to be scarce, despite the fact that the European Union project, EUScreen, collected unofficial data from 38 collaborating European institutions. The objectives of this systematic review were as follows: (a) to identify the most recent (in a 20-year span) literature information about UNHS programs in Europe and (b) to provide data on the procedures used to assess the population, the intervention policies, and on the estimated prevalence of congenital hearing loss with emphasis on the bilateral hearing loss cases. Queries were conducted via the Pubmed, Scopus and Google Scholar databases for the time period of 2004-2024.