: This study of asthma was performed to evaluate annual trends in emergency department (ED) for 10 years. Weather and air pollution factors affecting asthma were also studied in order to identify the important factors and alert the public in advance. : A survey of ambulatory-treated asthma patients was performed and the correlations with weather and air pollution factors examined in a cohort of one million patients in 2010. The fixed-cohort study analyzed trends, medical costs, and annual prevalence grouped by age and gender. : The number of asthma patients visiting EDs and non-emergency (non-ED) clinics significantly increased, with average annual percentage changes (AAPCs) of 2.3 and 4.6%, respectively. The average direct medical cost for EDs was increased significantly as compared with that of non-ED visits. Classification of asthma visits by hospital level indicated that local hospitals and others exhibited a significantly increasing trend (AAPC =15.3% [95% CI: 14.3-16.2]). The annual prevalence of asthma in males, females, and children was significantly increased (AAPCs of 1.5, 1.8, and 3.9%, respectively). Asthma patient hospitalizations were significantly correlated with temperature, humidity, and air pollution factors. : The number of non-ED visits due to asthma increased, and the average direct medical cost for ED admissions also increased. Asthma patients tended to visit local hospitals primarily. Asthma visits by children increased, but a decrease was observed in adults. The number of hospitalized asthma patients was negatively correlated with temperature and humidity but positively correlated with the levels of PM, PM, and NO.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02770903.2018.1497649DOI Listing

Publication Analysis

Top Keywords

air pollution
16
asthma patients
16
asthma
12
weather air
12
pollution factors
12
survey ambulatory-treated
8
ambulatory-treated asthma
8
annual prevalence
8
increased average
8
average direct
8

Similar Publications

Introduction: Short-term exposure to air pollution may worsen the course of ischemic heart disease (IHD), causing acute and chronic coronary syndromes.

Objectives: This study aimed to assess the risk of hospital admission due to chronic and acute coronary syndromes (ACS) after exposure to various air pollutants in Poland.

Methods: In this time-series study, the risk of hospital admission due to IHD over 3 days from exposure to several air pollutants was evaluated.

View Article and Find Full Text PDF

Enhancing Droplet Spreading on a Hydrophobic Plant Surface by Surfactant/Cellulose Nanocrystal Complexes.

ACS Nano

January 2025

Department of Chemical Engineering, Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.

A surfactant is an efficient and common additive used to enhance the spreading of droplets on hydrophobic surfaces. However, a high surfactant concentration is required to achieve the desired performance, resulting in environmental pollution and increased costs. Additionally, the pesticide loading capacity of surfactants at low concentrations (below their critical micelle concentrations) is a concern.

View Article and Find Full Text PDF

Atmospheric Deposition of Microplastics in South Central Appalachia in the United States.

ACS EST Air

January 2025

Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States.

Due to the increased prevalence of plastic pollution globally, atmospheric deposition of microplastics (MPs) is a significant issue that needs to be better understood to identify potential consequences for human health. This study is the first to quantify and characterize atmospheric MP deposition in the Eastern United States. Passive sampling was conducted at two locations within the Eastern United States, specifically in remote South Central Appalachia, from March to September 2023.

View Article and Find Full Text PDF

Spatiotemporal Mapping of Ultrafine Particle Fluxes in an Office HVAC System with a Diffusion Charger Sensor Array.

ACS EST Air

January 2025

Lyles School of Civil & Construction Engineering, Purdue University, West Lafayette, Indiana 47907, United States.

Commercial HVAC systems intended to mitigate indoor air pollution are operated based on standards that exclude aerosols with smaller diameters, such as ultrafine particles (UFPs, D ≤ 100 nm), which dominate a large proportion of indoor and outdoor number-based particle size distributions. UFPs generated from occupant activities or infiltrating from the outdoors can be recirculated and accumulate indoors when they are not successfully filtered by an air handling unit. Monitoring UFPs in real occupied environments is vital to understanding these source and mitigation dynamics, but capturing their rapid transience across multiple locations can be challenging due to high-cost instrumentation.

View Article and Find Full Text PDF

Background: Air pollution is a significant environmental risk factor for cardiovascular diseases (CVDs), but its impact on African populations is under-researched due to limited air quality data and health studies.

Objectives: The purpose of this study was to synthesize available research on the effects of air pollution on CVDs outcomes in African populations, identify knowledge gaps, and suggest areas for research and policy intervention.

Methods: A systematic search of PubMed was conducted using terms capturing criteria ambient air pollutants (for example particulate matter, nitrogen dioxide, ozone, and sulfur dioxide) and CVDs and countries in Africa.

View Article and Find Full Text PDF