Objective: To compare long-term outcomes and erosion rates of 3.5-cm artificial urinary sphincter (AUS) cuffs vs larger cuffs amongst men with stress urinary incontinence (SUI), with and without a history of pelvic radiotherapy (RT).

Patients And Methods: We reviewed the records of all men who underwent AUS placement by a single surgeon between September 2009 and June 2017 at our tertiary urban medical centre. A uniform perineal approach was used to ensure cuff placement around the most proximal corpus spongiosum after precise spongiosal measurement. Patients were stratified by cuff size and RT status, and patient demographics and surgical outcomes were analysed. Cases of AUS revision in which a new cuff was not placed were excluded. Success was defined as patient-reported pad use of ≤1 pad/day.

Results: Amongst 410 cases included in the analysis, the 3.5-cm cuff was used in 166 (40.5%), whilst 244 (59.5%) received larger cuffs (≥4.0 cm). Over a median follow-up of 50 months, there was AUS cuff erosion in 44 patients at a rate nearly identical in the 3.5-cm cuff (10.8%, 18/166) and the ≥4-cm cuff groups (10.7%, 26/244, P = 0.7). On multivariate logistic regression, clinical factors associated with AUS cuff erosion included a history of pelvic RT, prior AUS cuff erosion, prior urethroplasty, and a history of inflatable penile prosthesis (IPP) placement. Patient demographics were similar between the cuff-size groups; including age, body mass index, comorbidities, smoking history, RT history, prior AUS, and prior IPP placement. Continence rates were high amongst all AUS patients, with similar success in both groups (82% for 3.5-cm cuff, 90% for ≥4-cm cuff, P = 0.1).

Conclusions: After 8 years of experience and extended follow-up, the outcomes of the 3.5-cm AUS cuff appear to be similar to ≥4-cm cuffs for effectiveness and rates of urethral erosion. RT patients have a higher risk of cuff erosion regardless of cuff size.

Download full-text PDF

Source
http://dx.doi.org/10.1111/bju.14483DOI Listing

Publication Analysis

Top Keywords

aus cuff
16
cuff erosion
16
cuff
14
larger cuffs
12
35-cm cuff
12
aus
9
erosion rates
8
rates 35-cm
8
35-cm artificial
8
artificial urinary
8

Similar Publications

Purpose: To evaluate transperineal reanastomosis (TRPA) combined with incontinence surgery as a complex treatment for recurring vesicourethral anastomosis stenosis (VUAS) after radical prostatectomy (RP).

Methods: Retrospective analysis of 8 patients who underwent TRPA for recurring VUAS. Detailed preoperative and follow up data were assessed.

View Article and Find Full Text PDF

Objectives: To evaluate the efficacy of artificial urinary sphincter (AUS) implantation in men with stress urinary incontinence post-radical prostatectomy and the complication burden with a focus on identifying potential risk factors for reoperation as well as determining the fate of revision surgeries.

Methods: Retrospective analysis of consecutive patients undergoing primary AUS (pAUS) and revision AUS (rAUS) implantation at a tertiary centre. Logistic regression was employed to identify risk factors for reoperation associated with non-mechanical failures.

View Article and Find Full Text PDF

RAM2: animal study for safety evaluation of the new artificial urinary sphincter uroactive on a castrated RAM model.

World J Urol

November 2024

Department of Urology, Sorbonne Université, AP-HP, Sorbonne Université, Pitié-Salpêtrière Academic Hospital, Assistance Publique-Hôpitaux de Paris, 75013, Paris, France.

Article Synopsis
  • The study aimed to evaluate the safety of a new electronic artificial urinary sphincter (UroActive™) in castrated rams to treat severe urinary incontinence.
  • Twenty rams were implanted with the device and monitored over various time frames, while a sham group was also included for comparison.
  • The results showed successful implantation with minimal complications; only two rams developed infections, but overall, the device was deemed suitable for implantation without signs of significant adverse effects.
View Article and Find Full Text PDF

Objective: To discuss the long-term results of our vessel-sparing non-transecting approach (vspEPA) to perform anastomotic urethroplasty at the posterior urethra. We avoid transecting the bulbar arteries to preserve the antegrade vascularization of the urethra. We hypothesize that vspEPA is feasible, safe, and not inferior to the traditional transecting technique.

View Article and Find Full Text PDF
Article Synopsis
  • This study looked at how well an artificial urinary sphincter (AUS) can help men with severe bladder control issues caused by prostate cancer treatment.
  • Out of 20 men who received the AUS, 70% were able to stay dry with only one pad a day, while some had mild complications.
  • Overall, the AUS was found to be effective and improved the quality of life for most of the patients.
View Article and Find Full Text PDF