This work aims to investigate the influence of intrinsic and extrinsic factors on the physical resolution of the transmission electron backscattered diffraction technique (t-EBSD) in aluminum and silver. Here, we focus on the intrinsic factors, namely, atomic number and thickness of the specimen, and extrinsic set-up factors, which include the electron beam voltage, working distance, and specimen tilt. The working distance and tilt angle, which are selected as 12 mm and 60° for Al and 12 mm and 50° for Ag, respectively, reveal a sharp pattern with high contrast. The physical resolutions at the lateral and longitudinal directions depend on the depth resolution. The depth and lateral and longitudinal resolutions increase in Al but decrease in Ag with increased accelerating voltage. The decrease in specimen thickness for Al and Ag from 400 nm to 100 nm reduces the lateral and longitudinal resolutions. The most ideal depth and lateral and longitudinal resolutions obtained under a thickness of 100 nm are 22.7, 18.9, and 33.7 nm at 30 kV for Ag and 34.7, 22.8, and 36.6 nm at 15 kV for Al, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2018.06.019DOI Listing

Publication Analysis

Top Keywords

lateral longitudinal
16
longitudinal resolutions
12
resolution transmission
8
transmission electron
8
aluminum silver
8
atomic number
8
working distance
8
depth lateral
8
electron backscatter
4
backscatter diffraction
4

Similar Publications

Ultrasonic time-of-flight diffraction (TOFD) technique is applied to non-destructive testing in engineering, but the dead zone influences its applicable range. Alternative TOFD techniques adopt the indirect diffracted waves having long propagation times to decouple from the lateral wave and detect near-surface defects. It should be noted that the applicability of these diffracted waves varies with parameter conditions employed for detection, e.

View Article and Find Full Text PDF

Verification imaging in prostate MR-only radiotherapy: Are fiducial markers necessary?

Radiography (Lond)

December 2024

Newcastle Upon Tyne Hospitals NHS Foundation Trust, Northern Centre for Cancer Care, Newcastle Upon Tyne, United Kingdom; Newcastle University, Translational and Clinical Research Institute, Newcastle Upon Tyne, United Kingdom.

Purpose/objective: MR-only radiotherapy planning exploits the benefits of MRI soft-tissue delineation, whilst negating the registration inaccuracies caused by MRI CT fusion. Fiducial markers have conventionally been used in prostate radiotherapy to reduce on-treatment image matching variability. However, this is an invasive procedure for the patient, and presents technical difficulties in an MR-only pathway as fiducial markers are difficult to visualise on MRI.

View Article and Find Full Text PDF

A comparison of traffic crash and connected vehicle event data on a freeway corridor with Hard-Shoulder Running.

Accid Anal Prev

December 2024

Global Data Insights & Analytics, Ford Motor Company, United States. Electronic address:

Police crash reports have traditionally been the primary data source for research and development projects aimed at improving traffic safety. However, there are important limitations of such data, particularly the relative infrequency of crashes on a site-by-site basis in many contexts. Crash analyses often require multiple years of data and the use of such data for short-term evaluations creates challenges.

View Article and Find Full Text PDF

Supine postures are increasingly adopted in medical transport, long-duration flights, and other healthcare environments. This study is aimed to identify the effect of vibration direction and magnitude on the objective and subjective responses of the human body in a supine posture. The transmissibilities to the head, chest, abdomen, and thighs of 12 male subjects were measured with single-axis random vibrations in longitudinal ( axis), lateral ( axis), and vertical ( axis) direction at 0.

View Article and Find Full Text PDF

. Adult medulloblastoma (AMB) patients should receive postoperative craniospinal irradiation (CSI) as a standard treatment. Volumetric intensity-modulated arc therapy (VMAT) is a promising method for CSI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!