We demonstrate a highly sensitive and stable fiber-optic Fabry-Perot cantilever microphone based on fast demodulated white-light interferometry. The cavity length of the low-finesse Fabry-Perot interferometry is absolutely measured by realizing a high-speed demodulation method utilizing a full spectrum, with the advantages of both high resolution and large dynamic range. An acoustic test demonstrates high sensitivities and linear responsivities at frequencies below 2 kHz. The pressure responsivity and the noise-limited minimum detectable acoustic pressure level are measured to be 211.2 nm/Pa and 5  μPa/Hz, respectively, at the frequency of 1 kHz. Comparative experimental results show that the signal-to-noise ratio is over 10 times higher than a reference condenser microphone.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.43.003417DOI Listing

Publication Analysis

Top Keywords

fast demodulated
8
demodulated white-light
8
fiber-optic fabry-perot
8
fabry-perot cantilever
8
cantilever microphone
8
white-light interferometry-based
4
interferometry-based fiber-optic
4
microphone demonstrate
4
demonstrate highly
4
highly sensitive
4

Similar Publications

Multifrequency electrical impedance tomography (MFEIT) has shown great application prospects in the field of biomedical imaging. To realize high-precision multifrequency electrical impedance information acquisition, a high-precision MFEIT system with undersampling combined with a fast digital demodulation algorithm is proposed. The system is integrated with 16 electrodes, and semi-parallel acquisition is used.

View Article and Find Full Text PDF

The accuracy of ZPW-2000 frequency shift signal demodulation is related to the safety and efficiency of high-speed trains. This paper proposed a kind of ZPW-2000 frequency-shift signal detection algorithm based on improved Relaxation algorithm (ZFSD-IR) to address the issue of low accuracy in detecting ZPW-2000 frequency shift signal under strong noise interference, as the traditional fast Fourier transform (FFT) spectrum analysis methods are susceptible to fence effects and spectrum leakage effects. Firstly, the principle of ZPW-2000 jointless track circuit was analyzed, and then the ideal and simplified models of ZPW-2000 frequency shift signal were established, respectively.

View Article and Find Full Text PDF

Microstructures of additively manufactured metal parts are crucial since they determine the mechanical properties. The evolution of the microstructures during layer-wise printing is complex due to continuous re-melting and reheating effects. The current approach to studying this phenomenon relies on time-consuming numerical models such as finite element analysis due to the lack of effective sub-surface temperature measurement techniques.

View Article and Find Full Text PDF

Distributed Vibration Sensing Based on a Forward Transmission Polarization-Generated Carrier.

Sensors (Basel)

August 2024

Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.

For distributed fiber-optic sensors, slowly varying vibration signals down to 5 mHz are difficult to measure due to low signal-to-noise ratios. We propose and demonstrate a forward transmission-based distributed sensing system, combined with a polarization-generated carrier for detection bandwidth reduction, and cross-correlation for vibration positioning. By applying a higher-frequency carrier signal using a fast polarization controller, the initial phase of the known carrier frequency is monitored and analyzed to demodulate the vibration signal.

View Article and Find Full Text PDF

Pressure sensors prepared from sapphire exhibit excellent characteristics, including high-temperature resistance, high hardness, and resistance to electromagnetic interference. A Fast Fourier Transform and Mean Square Error (FFT-MSE) demodulation algorithm was employed to demodulate a sapphire sandwich-structure Fabry-Perot (F-P) pressure sensor. Through simulation analysis, the experimental results indicated that the demodulation error of the air cavity length in the range of 206 μm to 216 μm was less than 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!