A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Scanning Gel Electrochemical Microscopy for Topography and Electrochemical Imaging. | LitMetric

Scanning Gel Electrochemical Microscopy for Topography and Electrochemical Imaging.

Anal Chem

Université de Lorraine, CNRS, Laboratoire de Chimie Physique et Microbiologie pour les Matériaux et l'Environnement (LCPME) , UMR 7564 , Villers-lès-Nancy 54600 , France.

Published: August 2018

Scanning electrochemical probe techniques have been widely applied for analyzing the local electrochemical activity of surfaces and interfaces. In this work, we develop a new concept of carrying out local electrochemical measurements by localizing both the electrode and the electrolyte. This is achieved through a gel probe, which is prepared by electrodepositing chitosan-gelatin gel on a microdisk electrode. It is positioned in contact with the sample surface by shear force feedback. The preliminary results indicate that the topography of the sample can be mapped by tapping the probe and recording the coordinates at a given normalized shear force signal, while the local electrochemical activity can be retrieved from local measurements with the probe touching the sample surface. The technique is denoted as scanning gel electrochemical microscopy. As compared with existing techniques, it has a major advantage of operating in air with the electrolyte immobilized in gel. This would prevent the spreading and leakage of solution on the sample surface and may lead to field applications.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.8b01011DOI Listing

Publication Analysis

Top Keywords

local electrochemical
12
sample surface
12
scanning gel
8
gel electrochemical
8
electrochemical microscopy
8
electrochemical activity
8
shear force
8
electrochemical
7
microscopy topography
4
topography electrochemical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!